11
PX|22 Sheartec:II Planer \ Electrical Safety
Grounding Methods
DANGER!
THIS MACHINE MUST BE GROUNDED WHILE IN USE TO PROTECT THE OPERATOR FROM ELECTRIC SHOCK. IN ALL
CASES, MAKE CERTAIN THAT THE RECEPTACLE IN QUESTION IS PROPERLY GROUNDED. IF YOU ARE NOT SURE, HAVE
A QUALIFIED ELECTRICIAN CHECK THE RECEPTACLE.
Grounding Methods Provided by CSA Group. (A) Receptacle with nominal rating less than
150 volts. (B) 150 volt receptacle without grounding pin fitted with adapter. (C) 150-250
volt receptacle.
Fig C
1. All grounded, cord-connected machines:
In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric
current to reduce the risk of electric shock. This tool is equipped with an electric cord having an equipment-
grounding conductor and a grounding plug. The plug must be plugged into a matching outlet that is properly
installed and grounded in accordance with all local codes and ordinances.
Do not modify the plug provided - if it will not fit the outlet, have the proper outlet installed by a qualified
electrician.
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The
conductor with insulation having an outer surface that is green with or without yellow stripes is the
equipment-grounding conductor. If repair or replacement of the electric cord or plug is necessary, do not
connect the equipment-grounding conductor to a live terminal.
Summary of Contents for PX|22 Sheartec:II
Page 1: ...PX 22 Sheartec II Planer Owner s Manual MPLANPX2275 0130 MPLANPX2210 0130 3 10 2021...
Page 25: ...25 PX 22 Sheartec II Planer Setup Assembling FIGURES 10 12 DRO ADJUSTMENT...
Page 38: ...38 PX 22 Sheartec II Planer Wiring...
Page 39: ...39 PX 22 Sheartec II Planer Wiring...
Page 41: ...41 PX 22 Sheartec II Planer Replacement Parts Diagram Table Lift...
Page 42: ...42 PX 22 Sheartec II Planer Replacement Parts Diagram Stand Motor...