9
JX|12 & JX|16 Sheartec:II Jointers \ Electrical Safety
MJ16X100P-0130
VOLTAGE
220V
PHASE
3PH
HERTZ
60Hz
FULL LOAD AMPERAGE
20AMP
Below are RECOMMENDATIONS to be used for this machine based on the above
information. Variables that may affect this are:
·
Actual voltage supplied to the machine
·
Electrical code that must be met in your local province.
An electrician will verify that all the demands are met to properly wire the machine. If you have
absolutely any doubt when wiring this machine - please consult with a qualified electrician.
PLUG/RECEPTACLE
Not Included
WIRING (Gauge)
See Jacket Printing
CIRCUIT BREAKER
25Amp
If this information is different than what is stated on the Motor Specification Plate - omit this information. It
is possible that the documentation is outdated to a machine change - such as a different motor. Always
check the motor plate prior to any wiring. If any doubts, please consult a certified electrician.
Know when to use a time delay fuse! AKA Slow blow fuse. Generally, if the motor uses a start capacitor, a
time delay fuse is required. This type of fuse (circuit breaker) will not trip with the initial amperage needed
to start the machine, which is typically double that of the running amperage. Most woodworking machines
use this type of fuse.
Summary of Contents for JX12 Sheartec:II
Page 1: ...JX 12 JX 16 Sheartec II Jointers Owner s Manual MJ12X88P 0130 MJ16X100P 0130 3 11 2021...
Page 23: ...23 JX 12 JX 16 Sheartec II Jointers Setup Assembling...
Page 32: ...32 JX 12 JX 16 Sheartec II Jointers Wiring JX 12 ShearTec II MJ12X88P 0130...
Page 33: ...33 JX 12 JX 16 Sheartec II Jointers Wiring JX 16 ShearTec II MJ16X100P 0130...
Page 35: ...35 JX 12 JX 16 Sheartec II Jointers JX12 Sheartec II Parts Fence...
Page 36: ...36 JX 12 JX 16 Sheartec II Jointers JX12 Sheartec II Parts Stand Motor...
Page 45: ...45 JX 12 JX 16 Sheartec II Jointers JX16 Sheartec II Parts Fence...