ELECTRICITY
ELECTRICITY
4
LAGOON 62O
61
4.4 110 V - 220 V system
z
SHORE POWER
A shore power socket is located in the portside aft transom of cockpit.
It supplies power to the 110 V - 220 V system and the battery
chargers.
A second shore power socket, dedicated to air conditioning, is fitted
nearby if the boat is fitted with the air conditioning optional extra.
Before you plug in or unplug the boat/shore power supply cable,
switch off the shut off device connected to the shore supply.
Connect the boat/shore power supply cable in the boat before
connecting it to the shore supply socket. Unplug the boat/shore
supply cable on shore first.
Close the protecting cover of the shore supply socket when the plug
is not in use.
The shore power socket is protected by a circuit breaker located in
the portside engine bilge.
DANGER
Never let the end of the boat/shore supply cable
hang in the water ; the result may be an electric field
liable to hurt or kill the swimmers nearby.
220 V
SHORE POWER SOCKET N°1
50A
SHORE POWER SOCKET N°2
50A
z
GENERATOR
The generator is located in the service room of the foredeck.
Its function is to re-supply the batteries via the charger and supply
110 V - 220 V electricity on board.
On the boats fitted with 110 V - 60 HZ, 75% of the generator power
are for the equipments remaining in 220 V - 60 Hz and 25% for the
equipments working in 110 V - 60 Hz.
The generator is supplied by the port fuel tank.
OPERATION
You can start the generator either on the generator or by its control on
the electrical panel.
Make sure its fuel pull handle (access under the hob in the galley -
galley / hull version - and by the pull handles behind the hatch under
the bedside storage at the aft end of the port hull - galley / saloon
version) and its sea water cooling valve (access under the floor of the
port forward cabin) are open.
For the generator use and maintenance, refer to the instruction guide.
DIESEL OIL TRANSFER PUMP
In case of intensive use of the generator supplied by the port tanks,
use the transfer pump that makes possible the fuel circulation from
the starboard to the port tank.
Read information about its operation in chapter PROPULSION.
Summary of Contents for 620
Page 1: ......
Page 2: ......
Page 6: ......
Page 8: ......
Page 20: ......
Page 32: ......
Page 48: ......
Page 58: ...24 V SYSTEM LAGOON 62O 56 ELECTRICITY...
Page 60: ...58 ELECTRICITY LAGOON 62O 12 V SYSTEM...
Page 66: ...64 ELECTRICITY LAGOON 62O 220 VOLT 50HZ ELECTRICAL SYSTEM STANDARD EQUIPMENT...
Page 70: ...220 V SYSTEM LAGOON 62O 68 ELECTRICITY...
Page 71: ...110 V SYSTEM ELECTRICITY 4 LAGOON 62O 69...
Page 72: ......
Page 82: ......
Page 86: ......
Page 94: ...GRILL ON BOARD UTILITY LAGOON 62O 92...
Page 96: ......
Page 102: ...FUEL TRANSFER PUMP PROPULSION LAGOON 62O 100 FUEL TRANSFER PUMP...
Page 106: ......
Page 112: ......
Page 118: ......
Page 119: ......
Page 120: ......