VOLT -
user’s manual
user’s manual
- VOLT
Read the instructions carefully before using the voltage regulator
OPERATING INSTRUCIONS
1– IMPORTANT: Before plugging VOLT series into the power source, check whether the scope of the
input voltage is correct or not.
2– Plug VOLT series power cord into selected power source (220V).
3– Plug appliance into selected voltage output plug on VOLT series (220V)
4– Turn power switch of VOLT series on first, and then turn appliance power switch on, (NOTE: When
turning appliance on, always turn VOLT series on first, then appliance).
5– When turning appliance off, always turn appliance power switch off first, then turn VOLT series
power switch off.
FUSE OPERATION
1– If AVR fuse should blow out,turn appliance power switch off first. then turn VOLT series power
switch off,check that all connections are properly made.
2– Replace blown out VOLT series fuse with same type and rating fuse only.
PRECAUTIONS
1– The voltage of network input must conform to the demand of VOLT series, for optimum operation.
2– Connect all plugs securely.
3– Always turn VOLT series power switch on first, then turn appliance power switch on first, then turn
appliance power switch on. (Failure to do so may cause VOLT series fuse to blow).
4– For best results, do not use if over load condition exists.
5– Do not use in overly humid of flammable surroundings; avoid contact with any liquids.
6– The relationship between the output capacity and input voltage: picturel,long time overload is
forbidden.
FUNCTIONS
1– Supply constant voltage with electricity.
2– Hae TV & computer in stable and clear picture.
3– Extend life of appliance.
4– Avoid damage of appliance due to unstable input voltage.
APPLIANCE
• Computer
• TV&Radio
• Audio/Video
• Audio Equipmen
• Cash Register
• Light Equipment
• Alarm Systems
• Communication
SPECIFICATIONS
MODEL
INPUT VOLTAGE
OUTPUT VOLTAGE
FASE
FREQUENCY
VOLT 500VA
140V ~ 260V
220 ± 8%
single
50Hz
VOLT 1000VA
140V ~ 260V
220 ± 8%
single
50Hz
VOLT 2000VA
140V ~ 260V
220 ± 8%
single
50Hz
VOLT 3000VA
140V ~ 260V
220 ± 8%
single
50Hz
VOLT 5000VA
140V ~ 260V
220 ± 8%
single
50Hz
Overload
Urmost using time
20%
60 minutes
40%
32 minutes
60%
5 minutes
Vi = Input voltage
P2 = Output capacity
TAB.1
DIMENSION
33500500 VOLT-500:
205 x 135 x 110mm
33500505 VOLT-1000:
255 x 254 x 150mm
33500510 VOLT-2000:
255 x 254 x 150mm
33500515 VOLT-3000:
303 x 230 x 225mm
33500520 VOLT-5000:
303 x 230 x 225mm