c. Vacation Setting, VC displays in the middle, Economy setting display at right side.
Vacation days and its adjust displays at bottom.
Press the days minus or plus adjust to set Vacation days. Each step 1 day. Time
rage is from 0 to 99 days.
Press economy temperature setting minus or plus adjust to set Vacation economy
temperature setting.
Press SET to save setting and enter next feature setting.
Press OK to save setting and return to normal display.
The VC symbol will display at 2 digits of comfortable setting temperature. This
function will keep the set temperature until Vacation time count down to 0.
To cancel the Vacation setting, enter feature setting and Vacation setting to chan-
ge the day to 0 to cancel.
1�
2�
3�
4�
5�
6�
d.Heat / Cool cycle temperature differential, CYC displays at bottom, 1 or 2 in the
middle and select button at its left.
Press select button to select cycle temperature differential 1’C or 2’C.
Press SET to save setting and enter next feature setting.
Press OK to save setting and return to normal display.
1�
2�
3�
e. Back light enable/disable, bL displays at bottom, oF or oN in the middle and select
button at its left.
Press select button to select back light oF(OFF) or oN(ON 5 seconds after each
press button).
Press SET to save setting and enter next feature setting.
Press OK to save setting and return to normal display.
1�
2�
3�
f. Cooling or Heating start delay enable/disable. dLY displays at bottom, oF or oN in
the middle and select button at its left, HEAT or COOL displays in side the button
to show Heat or Cool start delay enable(oN) or disable(oF).
Press PROG under display to select delay setting for Heat or Cool. The HEAT or
COOL symbol will display.
Press select button to select start delay oF(OFF) or oN. The lockout will enable 5
minutes waiting between each system cycle.
Press SET to save setting and enter next feature setting.
Press OK to save setting and return to normal display.
1�
2�
3�
4�