g.Temperature Display Adjustment. TPA displays at bottom, room temperature at top
right and adjust value and its adjust at bottom right. HI(high) or Lo(low) in the mid-
dle.
Press adjust button to adjust display temperature. The adjustment range is 2.5’C
low to 2.5’C high. The thermostat was accurately calibrated at the factory but
you have option to change the display room temperature to match your previous
thermostat
Press SET to save setting and enter next feature setting.
Press OK to save setting and return to normal display.
1�
2�
3�
5. Manual Override enable and disable.
a. When system is programmed in Comfortable or Economy status, press the rever-
sed status button to manual override to reversed status and manual override symbol
displays on top. For example when in Comfortable, press Economy button, system
will enter economy status. This manual override will keep to the current hour en-
ding. If want to keep longer, press and hold the reversed button, manual override
time will display at clock position. The maximum time is 24 hours.
b. To cancel manual override, just press original status button, system will back to
program control. The manual override symbol will disappear. For example when
system in Economy override status, press Comfortable button will cancel it.
6. Battery low alarm:
when battery is low, LOWBTY displays and flashes at
top. You need to replace the battery.
7. Wiring
Wiring diagram
8. Specifications
Power Rate:
230V 50Hz
8A Resistive Load
Thermal Rate:
Measurement Temperature Range: 0’C to 35’C
Setting Temperature Range: 5’C to 30’C
Power:
2 x AA Alkaline Battery Operated.