Menu Description:

Main Menu:

 

 The Main Menu is used to access the MMT options and sub-menus.  The menu 

options are:
1.  Activate the Download feature
2.  Enter the Show Data Menu
3.  Activate the preset test time beep
4.  Set the Time
5.  Activate the Auto-Store feature
6.  Enter the Calibration procedure (for manufacturer use only. Contact Lafayette Instrument 

Co. for calibration.)  

7.  Exit the Menu

Menu items are selected by pressing the SCROLL button to move the cursor to the desired item 
and pressing the ENTER button to activate the item.  See Function Descriptions for details on 
each option.

Download:

The Download function allows data to be 
transferred to a computer for permanent 
storage.  The download is accomplished 
via infrared connection to a USB 
download device.  This device can be 
purchased separately from Lafayette 
Instrument (Model 01163IR).  

Function Descriptions:

Show Data Menu:

  The Show Data Menu allows the user to view stored data values or clear 

the memory registers.  The Show Data Menu is accessed by selecting SHOW DATA from the 
main menu screen.  Upon entering the menu, the user can 

1.  View the stored data.
2.  Delete the memory registers.
3.  View the version number.
3.  Exit the Menu.

Menu items are selected by pressing the SCROLL button to move the cursor to the desired 
item and pressing the ENTER button to activate the item.  See the sections (on page 9 and 10) 
regarding SHOW DATA, DELETING DATA REGISTERS, and VERSION IDENTIFIER for 
details on the operation of those menu items.

Summary of Contents for 01163

Page 1: ...P O Box 5729 Lafayette IN 47903 USA Tel 765 423 1505 800 428 7545 Fax 765 423 4111 E mail info lafayetteinstrument com www lafayetteinstrument com 2003 by Lafayette Instrument Company Inc All Rights R...

Page 2: ...oll LB KG Button 6 Enter Store Button 6 Menu Button 6 Main Measurement Screen 7 Menu Descriptions 8 Main Menu 8 Show Data Menu 8 Function Descriptions 9 Download 9 Show Data 9 Version Identi er 10 Del...

Page 3: ...bject The Lafayette MMT readily lends itself to large pre participation screenings or eld examinations where bulky more expensive systems do not The microprocessor control allows for storage of calibr...

Page 4: ...l test time Data storage for up to 52 tests in on board memory peak force and time to reach peak force Manual or automatic storage of data Dual measurement range 0 300lbs 136 1kg or 0 50lbs 22 6kg Sel...

Page 5: ...The unit is simply placed between the examiner s hand and the limb being tested The examiner s downward force is transmitted to the limb through the MMT unit The MMT is designed for one hand operatio...

Page 6: ...esetting Changing the range causes the MMT to automatically reset and clear all time and force values Scroll LB KG Button The LB KG button has dual functionality depending on which screen is accessed...

Page 7: ...e is displayed on the lower right of the Main Measurement Screen This value shows the total time that force has been applied After a test has ended this value shows the total length of the test in sec...

Page 8: ...ction Descriptions for details on each option Download The Download function allows data to be transferred to a computer for permanent storage The download is accomplished via infrared connection to a...

Page 9: ...n can not be established an error is given along with two audible beeps An option menu is then given which allows 1 a reattempt of communication or 2 canceling the operation The download device receiv...

Page 10: ...U button 2 Press the SCROLL button one 1 time to move the cursor to SHOW DATA 3 Press ENTER to turn the display to SHOW DATA menu 4 Press the SCROLL button two 2 times to move the cursor to CLEAR ALL...

Page 11: ...ove the cursor to BEEP 3 Press ENTER to turn on BEEP 4 Press the SCROLL button four 4 times to move the cursor to END 5 Press ENTER to exit the menu After the test time has ended no more data is measu...

Page 12: ...nwanted data may inadvertently be stored The MMT will store all tests including test trials and force readings from inadvertent pressing of the load cell If a test requires that only a select number o...

Page 13: ...limit Excessive force may cause permanent damage to the MMT or alter the calibration Caution Since the RESET button re zeros the MMT force should not be applied while the RESET button is pressed Reset...

Page 14: ...m Battery Saver Mode 1 Press one of these four buttons RESET MENU ENTER or SCROLL 2 Pressing the RANGE button does not wake up the MMT Low Battery Detection The MMT is equipped with circuitry to detec...

Page 15: ...3Photo CR17345 DL123ABU Panasonic CR123A Kodak K123L Acceptable Replacement Batteries Battery Change The battery of the MMT is accessed through a removable door in the face of the device The door is s...

Page 16: ...ired to change the stirrups In the event that a stirrup breaks or becomes soiled new stirrups may be ordered through Lafayette Instrument Company Error and Message Screen Summary The MMT has special m...

Page 17: ...FULL error is accompanied by two audible beeps The user must press the ENTER button to acknowledge and clear the warning They must then either discontinue storage by disabling the AUTO STORE feature o...

Page 18: ...ngth because it takes into account the length of the muscle being tested The Lafayette Manual Muscle Test System MMT can be used to obtain torque values through a series of basic calculations Torque i...

Page 19: ...Fax 765 423 4111 www lafayetteinstrument com E mail eval lafayetteinstrument com Fax 765 423 4111 www lafayetteinstrument com E mail eval lafayetteinstrument com Model 01163 User Instructions 19 Notes...

Page 20: ...PO Box The items should be packed well insured for full value and returned along with a cover letter explaining the malfunction Please also state the name of the Lafayette Instrument representative a...

Reviews: