background image

3700 Sagamore Parkway North . PO Box 5729 . Lafayette, IN 47903 USA . Ph: 765-423-1505                                   Fax: 765-423-4111 . www.lafayetteinstrument.com . E-mail:[email protected]

The Lafayette Manual Muscle Test System (MMT)

3700 Sagamore Parkway North . PO Box 5729 . Lafayette, IN 47903 USA . Ph: 765-423-1505                                   Fax: 765-423-4111 . www.lafayetteinstrument.com . E-mail:[email protected]

16

Caution:

 

You must turn off the MMT when changing stirrups.

Stirrup Change:

The MMT comes with three interchangeable stirrups.  Each stirrup is designed for different 
test applications depending upon what manual muscle test method is used. The flat stirrup is 
used for muscle testing in flat areas such as the forehead and back.  The large curved stirrup is 
used for large limbs such as the arms and legs.  The small flat stirrup is for small digits.  Each 
stirrup is padded for patient comfort.  To change stirrups, simply pull the stirrups off of the 
shaft and slide the new stirrup on.  The stirrups attach to the shaft via a “press fit.”  No tools 
are required to change the stirrups.  In the event that a stirrup breaks or becomes soiled, new 
stirrups may be ordered through Lafayette Instrument Company.

Error and Message Screen Summary:

The MMT has special message screens to indicate when certain operations are 
completed or when an error has occurred.  Selected error messages must be 
acknowledged with a user response before normal MMT operation can resume.  
Warning messages that require a user response are accompanied by two successive 
beeps.  The user must press ENTER or RESET to acknowledge the message and 
continue operations.

The message screens are as follows:

Low Battery Warning: 

This warning is given when a low battery condition has been detected.  The warning 
is accompanied by two audible beeps.  The warning is only given when the device is 
turned on or is waking up from Battery Saver Mode.  During normal operation, a low 
battery condition is also indicated by a battery icon on the Main Measurement Screen.  
The low battery warning is 
acknowledged and cleared by 
pressing the ENTER button.

Summary of Contents for 01163

Page 1: ...P O Box 5729 Lafayette IN 47903 USA Tel 765 423 1505 800 428 7545 Fax 765 423 4111 E mail info lafayetteinstrument com www lafayetteinstrument com 2003 by Lafayette Instrument Company Inc All Rights R...

Page 2: ...oll LB KG Button 6 Enter Store Button 6 Menu Button 6 Main Measurement Screen 7 Menu Descriptions 8 Main Menu 8 Show Data Menu 8 Function Descriptions 9 Download 9 Show Data 9 Version Identi er 10 Del...

Page 3: ...bject The Lafayette MMT readily lends itself to large pre participation screenings or eld examinations where bulky more expensive systems do not The microprocessor control allows for storage of calibr...

Page 4: ...l test time Data storage for up to 52 tests in on board memory peak force and time to reach peak force Manual or automatic storage of data Dual measurement range 0 300lbs 136 1kg or 0 50lbs 22 6kg Sel...

Page 5: ...The unit is simply placed between the examiner s hand and the limb being tested The examiner s downward force is transmitted to the limb through the MMT unit The MMT is designed for one hand operatio...

Page 6: ...esetting Changing the range causes the MMT to automatically reset and clear all time and force values Scroll LB KG Button The LB KG button has dual functionality depending on which screen is accessed...

Page 7: ...e is displayed on the lower right of the Main Measurement Screen This value shows the total time that force has been applied After a test has ended this value shows the total length of the test in sec...

Page 8: ...ction Descriptions for details on each option Download The Download function allows data to be transferred to a computer for permanent storage The download is accomplished via infrared connection to a...

Page 9: ...n can not be established an error is given along with two audible beeps An option menu is then given which allows 1 a reattempt of communication or 2 canceling the operation The download device receiv...

Page 10: ...U button 2 Press the SCROLL button one 1 time to move the cursor to SHOW DATA 3 Press ENTER to turn the display to SHOW DATA menu 4 Press the SCROLL button two 2 times to move the cursor to CLEAR ALL...

Page 11: ...ove the cursor to BEEP 3 Press ENTER to turn on BEEP 4 Press the SCROLL button four 4 times to move the cursor to END 5 Press ENTER to exit the menu After the test time has ended no more data is measu...

Page 12: ...nwanted data may inadvertently be stored The MMT will store all tests including test trials and force readings from inadvertent pressing of the load cell If a test requires that only a select number o...

Page 13: ...limit Excessive force may cause permanent damage to the MMT or alter the calibration Caution Since the RESET button re zeros the MMT force should not be applied while the RESET button is pressed Reset...

Page 14: ...m Battery Saver Mode 1 Press one of these four buttons RESET MENU ENTER or SCROLL 2 Pressing the RANGE button does not wake up the MMT Low Battery Detection The MMT is equipped with circuitry to detec...

Page 15: ...3Photo CR17345 DL123ABU Panasonic CR123A Kodak K123L Acceptable Replacement Batteries Battery Change The battery of the MMT is accessed through a removable door in the face of the device The door is s...

Page 16: ...ired to change the stirrups In the event that a stirrup breaks or becomes soiled new stirrups may be ordered through Lafayette Instrument Company Error and Message Screen Summary The MMT has special m...

Page 17: ...FULL error is accompanied by two audible beeps The user must press the ENTER button to acknowledge and clear the warning They must then either discontinue storage by disabling the AUTO STORE feature o...

Page 18: ...ngth because it takes into account the length of the muscle being tested The Lafayette Manual Muscle Test System MMT can be used to obtain torque values through a series of basic calculations Torque i...

Page 19: ...Fax 765 423 4111 www lafayetteinstrument com E mail eval lafayetteinstrument com Fax 765 423 4111 www lafayetteinstrument com E mail eval lafayetteinstrument com Model 01163 User Instructions 19 Notes...

Page 20: ...PO Box The items should be packed well insured for full value and returned along with a cover letter explaining the malfunction Please also state the name of the Lafayette Instrument representative a...

Reviews: