![laerdal Nursing Baby VitalSim Manual Download Page 12](http://html2.mh-extra.com/html/laerdal/nursing-baby-vitalsim/nursing-baby-vitalsim_manual_3285294012.webp)
Vocal Sounds and Auscultation of heart,
breath and bowel sounds:
Connect Nursing Baby to VitalSim Unit, via cable located on
right side of manikin. (Photo 3)
See VitalSim DFU for complete Heart, Breath
and Bowel Sound Auscultation
Photo 3
Genitalia-
Both male and female genitalia have been provided for urinary
catheterization and enema training procedures.
To Assemble
1. Remove chest skin from torso by detaching straps on
back of manikin.
2. Remove pelvic pin (Photo 4) to release urinary
reservoir.
NOTE: Pelvic Pin must be replaced.
Urinary Reservoir
Plug
Urinary Reservoir
Pelvic Pin
Photo 4
Laerdal