background image

15

T

ekniske data

T

echnical data

Bestillingsnr

.

Ordering number

Nettspenning

Input voltage

Ladespenning

Char

ging voltage

V

edlikehold

Float char

ge

Strøm

Current

Dimensjoner (H,B,D)

Dimensions (H,W

,D)

Tetthetsgrad

W

ater protection

V

ekt

W

eight

4041DMC

230V

AC

14,40 VDC

13,30 VDC

2x5 

A

245x135x80 

mm

IP66

4,5 

kg

4041OPC

230V

AC

14,40 VDC

13,30 VDC

2x5 

A

245x135x80 

mm

IP66

4,5 

kg

4041DUC

230V

AC

14,40 VDC

13,30 VDC

2x5 

A

245x135x80 

mm

IP66

4,5 

kg

4041DU1

10C

115V

AC

14,40 VDC

13,30 VDC

2x5 

A

245x135x80 

mm

IP66

4,5kg

4041UNC

230V

AC

14,40 VDC

13,30 VDC

10A

245x135x80 

mm

IP66

4,5 

kg

4041EMC

230V

AC

14,40 VDC

13,30 VDC

10A

245x135x80 

mm

IP66

4,5 

kg

4041DXC

230V

AC

14,40 VDC

13,30 VDC

2x10 

A

245x220x1

10 

mm

IP66

9,3 

kg

4041MXC

230V

AC

14,40 VDC

13,30 VDC

4x5 

A

245x220x1

10 

mm

IP66

9,3 

kg

4041MXMILC

230V

AC

14,40 VDC

13,30 VDC

4x5 

A

245x220x1

10 

mm

IP66

9,3 

kg

Summary of Contents for 4041-2

Page 1: ...ersal 6 4041EMC Marine 6 4041DXC Duplex 8 4041MXC Multiplex 10 4041MXMILC Multiplex MILSPEC 12 Installasjonsprosedyre Installing procedure 14 Tekniske data Technical data 15 Service notater Service notes 16 Batterilader Battery charger Batteriladeren er i samsvar med The battery charger is in conformity with Standard LVD 73 23 EØF EMC EN55014 ...

Page 2: ...e strøm fra batteri når nettet ikke er tilkoblet Laderens kanaler kan tilkobles hvert batteri for seg uten å ta hensyn til batterienes sammenkoplinger Flere kanaler kan tilkobles parallellt til ett batteri Laderen bør monteres så nær batteriene som mulig Ved lange strekk bruk sikring ved batteri ADVARSEL Monter ikke laderen i brannfarlig miljø GASS Under lading utvikles knallgass som er meget eksp...

Page 3: ...teries regardless of inter connections between the batteries Multi channels may be connected in parallell to one battery The charger should be placed as close to the battery as possible If used over greater distances use a circuit breaker near the batteries WARNING Do not mount the charger near any combustible area GASSING Explosive oxyhydrogen gas may be formed in the charging process It ignites ...

Page 4: ...GER 1 2 4041 2 IP 67 YELLOW CHARGING GREEN FULLY CHARGED RED FAILURE 4041 2 IP 67 DUAL MARINE BATTERY CHARGER YELLOW CHARGING GREEN FULLY CHARGED RED FAILURE 1 2 Monteringsbeskrivelse Fest laderen til veggen med 3 skruer 1 Monter skrue i punkt A 2 Løft opp laderen til den stopper 3 Monter skruer i punkter B og C A B C Installing instructions Fasten the charger with 3 bolts 1 Mount the first bolt i...

Page 5: ...nbefales å montere sikringer på ladekabler nær batteriene Connection of mains input voltage Terminals L and N to the left is mains input The free connections can be used as output to other con sumers The charger is double insulated and should not be connected to ground Connecting the relay optional Terminal P3 is an isolated 1 pole re lay that is activated when the input voltage is present Can be ...

Page 6: ...lse Fest laderen til veggen med 3 skruer 1 Monter skrue i punkt A 2 Løft opp laderen til den stopper 3 Monter skruer i punkter B og C Installing instructions Fasten the charger with 3 bolts 1 Mount the first bolt in point A 2 Lift the charger up until it stops 3 Mount bolts in points B and C 4041EMC 4041UNC 4041 2 IP 67 UNIVERSAL BATTERY CHARGER YELLOW CHARGING GREEN FULLY CHARGED RED FAILURE ...

Page 7: ...tem Det anbefales å montere sikringer på ladekabler nær batteriene Connection of mains input voltage Terminals L and N to the left is mains input The free connections can be used as output to other con sumers The charger is double insulated and should not be connected to ground Connecting the relay optional Terminal P3 is an isolated 1 pole re lay that is activated when the input voltage is presen...

Page 8: ... Fest laderen til veggen med 3 skruer 1 Monter skrue i punkt A 2 Løft opp laderen til den stopper 3 Monter skruer i punkter B og C Installing instructions Fasten the charger with 3 bolts 1 Mount the first bolt in point A 2 Lift the charger up until it stops 3 Mount bolts in points B and C 8 4041DXC ...

Page 9: ... montere sikringer på ladekabler nær batteriene Connection of mains input voltage Terminals L and N to the left is mains input The free connections can be used as output to other con sumers The charger is double insulated and should not be connected to ground Connecting the relay optional Terminal P3 is an isolated 1 pole re lay that is activated when the input voltage is present Can be used as al...

Page 10: ...else Fest laderen til veggen med 3 skruer 1 Monter skrue i punkt A 2 Løft opp laderen til den stopper 3 Monter skruer i punkter B og C Installing instructions Fasten the charger with 3 bolts 1 Mount the first bolt in point A 2 Lift the charger up until it stops 3 Mount bolts in points B and C 4041MXC ...

Page 11: ...ales å montere sikringer på ladekabler nær batteriene Connection of mains input voltage Terminals L and N to the left is mains input The free connections can be used as output to other con sumers The charger is double insulated and should not be connected to ground Connecting the relay optional Terminal P3 is an isolated 1 pole re lay that is activated when the input voltage is present Can be used...

Page 12: ...ØD LADDNING PÅGÅR FULLADDAD FEL GUL GRÖN RÖD A B C Monteringsbeskrivelse Fest laderen til veggen med 3 skruer 1 Monter skrue i punkt A 2 Løft opp laderen til den stopper 3 Monter skruer i punkter B og C Installing instructions Fasten the charger with 3 bolts 1 Put the first bolt in point A 2 Lift the charger up until it stops 3 Mount bolts in points B and C 4041MXMILC ...

Page 13: ...ales å montere sikringer på ladekabler nær batteriene Connection of mains input voltage Terminals L and N to the left is mains input The free connections can be used as output to other con sumers The charger is double insulated and should not be connected to ground Connecting the relay optional Terminal P3 is an isolated 1 pole re lay that is activated when the input voltage is present Can be used...

Page 14: ...A into the square channel 2 Insert wire cross section max 2 5mm 3 Remove screwdriver 4 Check the connection Installasjonsprosedyre for fjærklemmer 1 Press en flat skrutrekker DIN5264 A inn i det firkantede hullet 2 Sett inn avisolert kabel maks 2 5mm 3 Dra ut skrutrekkeren 4 Kontroller koblingen ...

Page 15: ...40 VDC 13 30 VDC 2x5 A 245x135x80 mm IP66 4 5 kg 4041DUC 230VAC 14 40 VDC 13 30 VDC 2x5 A 245x135x80 mm IP66 4 5 kg 4041DU110C 115VAC 14 40 VDC 13 30 VDC 2x5 A 245x135x80 mm IP66 4 5kg 4041UNC 230VAC 14 40 VDC 13 30 VDC 10A 245x135x80 mm IP66 4 5 kg 4041EMC 230VAC 14 40 VDC 13 30 VDC 10A 245x135x80 mm IP66 4 5 kg 4041DXC 230VAC 14 40 VDC 13 30 VDC 2x10 A 245x220x110 mm IP66 9 3 kg 4041MXC 230VAC 1...

Page 16: ...16 MAN40 Service notater Service notes ...