background image

 

 

INSTRUCTIONS FOR THE INSTALLER 

 

 

2.  

 

Figure No.3 -

 

Distances between chimney 

crown and roof ridge 

The  chimney  crown  must  clear  the 

highest  point  of  any  neighbouring  building 
or obstacle located within a 10m radius of 
the chimney outlet by more than 1m. 

 

Figure No.4 -

 

Distances between the 

chimney crown and objects within a 10m 

radius 

The  chimney  crown  must  clear  any 

neighbouring  building  or  obstacle  located 
within  a  radius  of  10m  to  20m  from  the 
chimney outlet. 

 

Figure No.5 -

 

Distances between the 

chimney crown and objects within a radius 

of between 10 and 20m 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Atlantic 600

Page 1: ...Atlantic 600 Instruction Book ...

Page 2: ...STALLER 5 2 1 Warning to installers 5 2 2 Room for installation 5 2 2 1 Ventilation of the room 5 2 2 2 Location of the appliance in the room 6 2 3 Installation of the appliance 6 2 3 1 Floor 6 2 3 2 Safety distances 6 2 3 3 Checks before lighting for the first time 6 2 3 4 Height adjustment and levelling the appliance 6 2 3 5 Connection to the flue 6 2 4 Chimney flue 6 2 4 1 Type of flue 6 2 4 2 ...

Page 3: ...1 4 1 3 Flue socket 15 4 1 4 Painted sheet steel cast iron parts 15 4 1 5 Firebox glass 15 4 2 Maintenance of the chimney flue 15 4 3 Important advice 15 TROUBLESHOOTING 16 BASIC BREAKDOWNS 17 DECLARATION OF PERFORMANCE 18 CE MARK 20 ...

Page 4: ...W 12 Efficiency at N H O 85 CO emission at 13 O2 at N H O 0 04 Gas mass flow at N H O g s 7 9 Gas temperature of flue at N H O ºC 252 Optimum flue draught Pa 12 Wood consumption beech at N H O Kg h 3 3 Dimensions of the firebox Width mm 530 Depth mm 280 Useful height mm 220 Maximum length of the logs cm 50 Volume heated 45w m at N H O m 267 Log load frequency h 1 Capacity of the ashpit L 1 5 Weigh...

Page 5: ...PRESENTATION OF THE APPLIANCE 4 1 Figure No 1 Dimensions of the Atlantic series in mm ...

Page 6: ...olutely crucial to ensure the suitable renewal of the air in the room in which the appliance is fitted the room must always have at least two permanent grilles or openings to the exterior in order to renew the air one for intake and the other for extraction For the installation of its appliances Lacunza recommends an additional section for these openings One of these two grilles must be situated h...

Page 7: ...tly positioned Make sure that the airtight joints on the flue circuit are in perfect condition Make sure that the doors close properly Make sure that all moving parts are fitted in place 2 3 4 Height adjustment and levelling the appliance The appliance must be perfectly level horizontally and vertically both at the front and on the sides use a spirit level 2 3 5 Connection to the flue The applianc...

Page 8: ...raught cowl a static cowl or a smoke extraction fan or reshape the chimney Never make 90º bends due to the great loss of draught they cause and reduce 45º bends down to an absolute minimum Each 45º bend is equivalent to a 0 5m reduction in flue length Horizontal flue sections should not be installed because they cut updraught a great deal If the flue draws at more than 20 Pa then an effective damp...

Page 9: ...tacle located within a 10m radius of the chimney outlet by more than 1m Figure No 4 Distances between the chimney crown and objects within a 10m radius The chimney crown must clear any neighbouring building or obstacle located within a radius of 10m to 20m from the chimney outlet Figure No 5 Distances between the chimney crown and objects within a radius of between 10 and 20m ...

Page 10: ...anliness height verticality straightness chimney crown etc If sufficient updraught is not achieved by correcting the flue installation Lacunza supplies an accessory for exceptional cases a part which seals the top of the front part of the appliance and helps prevent smoke escaping into the room Logically this reduces both the view of the fire and the loading aperture on the appliance Figure No 6 A...

Page 11: ...ely chopped wood produces greater heat output but also burns more quickly Optimum fuels Beech Other fuels Oak chestnut ash maple birch elm etc Pine and eucalyptus logs are low density and produce very long flames and may cause the parts of the appliance to wear out more quickly than normal Resinous wood may mean that the appliance and the flue need to be cleaned more often Non permitted fuels All ...

Page 12: ...n of the parts of the appliance 3 2 1 Operating components Figure No 8 Operating components on the appliance A Firebox door handle B Primary air intake o B1 open right o B2 closed left C Secondary air intake o C1 open right o C2 closed left ...

Page 13: ... of operation If you notice water around the appliance this is produced by the condensation of the moisture in the wood on lighting the fire This condensation will no longer appear when the appliance has been lit three or four times and has adapted to its flue If it does not disappear then check the flue draught length and diameter of the flue flue insulation airtightness and the humidity of the w...

Page 14: ...ce and reduces emissions Figure No 9 Double combustion air intake open Figure No 10 Double combustion air intake closed IMPORTANT The appliance is exposed to extreme changes in temperature and may as a result make noises when in operation These noises are a natural result of expansion contraction of the parts which make up the appliance Do not be alarmed by noises of this kind In order to obtain m...

Page 15: ...the stainless steel reinforcement In order to do this draw it towards the front of the appliance to release it from the vermiculite parts Figure No 11 First movement to release the reinforcement The vermiculite deflectors can then be extracted as shown Figure No 12 Extracting the vermiculite deflectors Extract the rest of the firebox vermiculite Figure No 13 Extract the rest of firebox vermiculite...

Page 16: ...ner for longer However the glass may get dirty the longer the appliance is used Special degreasing products designed for the purpose should be used to clean it Clean when the glass is cold and taking care not to apply the glass cleaner directly onto the glass as it could come into contact with the door seal cord and damage it 4 2 Maintenance of the chimney flue VERY IMPORTANT In order to avoid inc...

Page 17: ... continually burn chips carpentry scraps plywood pallets etc Cold flue Heat up the flue by burning a piece of paper in the firebox Smoke during burning The room is at low pressure In rooms with Controlled Mechanical Ventilation leave an outdoor window ajar until the fire is fully alight Too little wood loaded Load as recommended Loads notably smaller than those recommended lead to low smoke temper...

Page 18: ...ecer Vermiculita Trasera DCHA 1 6 5020000931 Ocean 600 Recer Cjto Registro 1º 1 7 502570000007 Pieza móvil registro secundario Ocean 1 8 5020000932 Ocean 600 Recer Refuerzo deflector vermiculita 1 9 502620000004 Cristal hogar Atlantic 600 1 10 509020000042 Cordón Negro Ø13mm 3m 11 500000000510 Cordon plano pelos 8x2mm 2m 12 5040000904 Nickel Adour Parrilla hogar 1 13 5020000933 Ocean 600 Recer Ver...

Page 19: ...DECLARATION OF PERFORMANCE 18 7 DECLARATION OF PERFORMANCE ...

Page 20: ...DECLARATION OF PERFORMANCE 19 7 ...

Page 21: ...CE MARK 20 8 CE MARK ...

Page 22: ......

Page 23: ......

Page 24: ...LACUNZA KALOR GROUP S A L Pol Ind Ibarrea s n 31800 Alsasua Navarra Spain Tel 00 34 948 56 35 11 Fax 00 34 948 56 35 05 e mail comercial lacunza net Website www lacunza net EDITION 0 ...

Reviews: