Manual SmartPicker AOM Rev. A ENG
LaCoSys Nov 2017
-11-
The PHOTODIODE-Monitor port provides a monitoring signal for the photodiode input. Here we advise to
check level. Minimum 50mV (150mV for optimal function)
The Photodiode-Monitor output is optimized for an output impedance of 50
Ω.
Shortening the
output may lead to irreparable device damage.
The Photodiode-Monitor output is optimized for an output impedance of 50
Ω
. For other output
impedance values the voltages are not correct.
3.7
Mains
Input
Connector:
DC-PLUG 2,5mm
Voltage:
24VDC
Current:
2 A max.
Use only the delivered power supply. The supplied mains cable with an IEC 60320 C13 connector or an
identical one must be used. It can be custom- or country specific.
3.8
USB-Connection
Please use a standard USB A-B cable for connecting the device with a PC. The installation of the needed drivers
takes place automatically in most cases. More details can be read in chapter 4.3.
3.9
AOM
–
INTERFACE
Output
Connector:
SUB D 15 (f)
PIN 1 5V
PIN 2,4,7,10,12,14 GND
PIN 3
TTL-OUT @5mA
PIN 5,6,8 NC
PIN 9,11,13,15 24V-DC (max.2A)
The AOM interface provide an easy connection for example RF-Driver from manufacturer AA
http://www.aaoptoelectronic.com/Documents/MODAxx-MODAGxx-2014.pdf
Here we advise to use the TTL-Version.
The AOM-Interface output is optimized for 24V-DC Drivers. Shortening the output may lead to
irreparable device damage.