Managed Media Converter Chassis System  

1  User Manual 

Preface 

The Managed Media Converter Chassis System supports the Media Converter Chassis to 

monitor the each Media Converter ( CO ) or Chassis Manager status and to configure 

advanced function of the Managed Converter Chassis.  Through Out-band management 

via Web Browser utility to monitor/configure the Managed Media Converter Chassis 

System. 

This manual describes how to configure all Media Converter ( CO ), Chassis Manager and 

each Managed Converter Chassis, which features eight slots of Meida Converters ( CO or 

Chassis Manager ) in one Managed Converter Chassis, as well as the Remote side / 

Terminal Media Converter ( CPE ). 

The system allow to have 4 Managed Converter Chassis on one Managed System by 

using IN/OUT Port for stacking, all you require to do is simply slide in one Chassis Manager 

to any of Managed Converter Chassis in order to manage the system.. 

To get the most out of this manual, you should have an understanding of networking 

concepts such as bridging, IEEE 802.3 10Base-T Ethernet, IEEE802.3u 100Base-TX/FX 

Fast Ethernet and local area networks (LANs). 

For more information about these topics, please refer to the Appendix. 

Summary of Contents for L-EMM100CO

Page 1: ...ach Managed Converter Chassis which features eight slots of Meida Converters CO or Chassis Manager in one Managed Converter Chassis as well as the Remote side TerminalMediaConverter CPE The system allow to have 4 Managed Converter Chassis on one Managed System by using IN OUT Port for stacking all you require to do is simply slide in one Chassis Manager toanyofManagedConverterChassisinordertomanag...

Page 2: ...nager 4 MediaConverter MC asCOside 6 MediaConverter Terminal asCPEside 8 8SlotManagedConverterChassis 9 SystemConfiguration 11 ConnectingtoPower 11 ChassisStacking 11 Web BasedBrowserInterface 12 LoggingontoTheManagedMediaConverterChassisSystem12 MainMenu 12 1 SystemChange 13 2 IPConfiguration 14 3 Chassis 14 4 Monitor 22 5 SNMPConfiguration 26 6 Alarm 27 7 Save 29 8 Default 31 9 UpdateFirmware 32...

Page 3: ...uration This chapter provides network managers and system administrators with information about howtoconfiguretheManagedMediaConverterChassisSystemviatheWebBrowser The reader of this document should be knowledgeable about network devices device configuration network management and Internet browers The user is assumed to be networkadministratorormanagerwithanunderstandingofnetworkoperations Applica...

Page 4: ...pe WDMsingle fiber bi direction transceivertransmitswith1550nm wavelengthandreceiveswith1310nmwavelength z Built in128KbitsRAMfordatabuffer z Built inCPUwith2MBytesFlash 8MBytesSDRAM z StatusLEDs z UsedwithaManagedChassis z Hot swappablewhenusedwithamanagedchassis z System Change Device Name New Password Old Password Version MAC address z IPConfiguration DHCP IPaddress Netmask DefaultGateway z Cha...

Page 5: ... LoopbackTest z MCHardwareMonitor Temperature SupplyVoltage z SNMP Configuration System Contact System Location Get Community Set Community z Alarm Alarm Configuration Hardware Alarm Configuration Alarm Mail Trap AlarmSNMP Trap z TFTPClientforSoftwareUpgrade z Telnet SNMPV1 V2 WebBrowser andTFTPManagement z EnterpriseMIB z UsedaswithaManagedChassis z Hot swappableinanySlotwhenusedwithamanagedchass...

Page 6: ...113 StorageTemperature 10 70 14 158 Humidity 5 95 non condensing Emission Compliance CEMarkClassA FCCPart15ClassA Dimensions 80mm W x124mm D x20mm H 3 15 W x4 88 D x0 79 H NetWeight 160g 0 35lb MediaConverter MC asCOside KeyFeatures z One channelmediaconversionbetween10 100Base TXand100Base FX z SupportAUTO NegotiationandAUTO MDIXfor10 100Base TXPort z Fibermediaallows Multi modefiberusingSC ST VF...

Page 7: ... 10Base T2 pairUTPCat 3 4 5 upto100m 328ft 100Base TX2 pairUTPCat 5 upto100m 328ft 100Base FX50or62 5 125umMulti modefiberopticcable 9or10 125umSingle modefiberopticcable SwitchingMethod Store and Forward ForwardingRate 14 880ppsfor10Mbps 148 810ppsfor100Mbps PowerConsumption 3WMax PhysicalSpecification Power 0 25A 12VDCPowerSupply OperatingTemperature 0 45 32 113 StorageTemperature 10 70 14 158 H...

Page 8: ...Builtin128KbitsRAMfordatabuffer zStatusLEDs zWall mountable zExternalPowerAdapter 0 25A 12VDC TechnicalSpecification LED PerUnit PW FA Power FailureAlarm PerPort 10 100TX LK AT Link Activity FD CL Full duplex Collision 100FX LK AT Link Activity EthernetStandards IEEE802 310Base T IEEE802 3u100Base TX 100Base FX Cable 10Base T2 pairUTPCat 3 4 5 upto100m 328ft 100Base TX2 pairUTPCat 5 upto100m 328ft...

Page 9: ...0mm H 3 15 W x4 88 D x0 79 H NetWeight 160g 0 35lb 8SlotManagedConverterChassis KeyFeatures zEachChassisHouses8Slots Converters zSlim1UHeight19 DesigntoSaveSpace zStackableuptoFourChassis upto32Converters zHotSwappable zSupportsPowerRedundancy TechnicalSpecifications LED PWR1 ForACPowerstatus PWR2 ForDCPowerstatus Fan1 Fan2 ForFanstatus STKIN STKOUT Forstackportstatus StackingPort RJ 45 StackingCa...

Page 10: ...tions Power ACInput 100 240V DCInput 2 67A 12VDC OperatingTemperature 0 45 32 113 StorageTemperature 10 70 14 158 Humidity 5 95 non condensing Emission Compliance CEMarkClassA FCCPart15ClassA Dimensions 440mm W x235mm D x44mm H 17 32 W x9 25 D x1 73 H NetWeight 3Kg 6 6lbs ...

Page 11: ...and configured as thought the entire stack were a single chassis manager The chassis stack is then accessed through a singleIPaddress The stacking ports are marked IN and OUT The RJ45 compliant cable must be connected from an IN port on one Switch to an OUT port on the next Switch in the stack The last two Switches at the top and bottom of the stack must also be connected from the IN port on one S...

Page 12: ...ible using a Web browser IE explorer Netscape Communication etc to open up the Managed Converter Chassis moniteringSystem LoggingontoTheManagedMediaConverterChassisSystem ThedefaultIPAddressfortheSystemis 192 168 1 10 andthereisnoneedtotypeinboth Loginname and password asdefault justsimplypress OK tostarttheMainScreen MainMenu ...

Page 13: ...eviceName Thissectionistosetyourown DeviceName 1 2 NewPassword Thissectionistosetyourown NewPassword 1 3 OldPassword Thissectionistoverifytheoldpasswordyousetbefore 1 4 Version ThisisanindicationoftheSoftwareversionforreference 1 5 MacAddress ThisistheinformationofMacAddressofyourDevice NOTE After configuring the Device need to press the Apply botton to save the setting ...

Page 14: ...ddress To allocate an IP Address for the Managed Converter Chassis the default IP is 192 168 1 10 2 3 Netmask TosettheNetmask thedefaultis 255 255 255 0 2 4 DefaultGateway TosetthedefaultGatewayaddressis 192 168 1 254 NOTE Afterconfigurationset needtopressthe Apply buttontosavethesetting 3 Chassis 3 1 ChassisHardwareMonitor Thissectiondivideto4differentManagedConverterChassiswithNo oneachChassisun...

Page 15: ...tus Thereare2FansinChassis Status On or Off Active MC There are 8slots for Media Converter or Chassis Manager Status Active or Inactive Uptime NOTE This menu can also be read simply point the Left hand side of Managed Converter Chassis on the top graphic of Chassis 0 3 where the Chassis Hardware Switch is 3 2 COMCStatus ThissectionyoucanseetheMediaConverter 1 8insideofChassis 0 3 Chassis Chassis 0...

Page 16: ... CollisionCount Media Port2 Type Current Model Link Status Receive Count Drop Count and CollisionCount NOTE If the Status needs to be calculated from fresh please press the Reset botton torestartthecounting NOTE This menu can also be read simply point the Left hand side of Managed Converter Chassis onthetop graphicof Chassis 0 wherethe ChassisHardwareSwitch is 3 3 COMCControl Chassis Chassis 0 3 M...

Page 17: ...urrentModel PortMode Auto or 10HD or 10FD or 100HD or 100FD FlowControl Disable or Enable MDIX Disable or Enable OutputRate Full or 25 or 50 or 75 InputRate Full or 25 or 50 or 75 MediaPort2 Type CurrentModel PortMode 100HD or 100FD FlowControl Disable or Enable InformingWayforReceivingOff MaintenanceFrame or Far End FaultPattern NOTE After configuration set need to press the Apply and Save button...

Page 18: ... inform speed duplex andauto negotiationinterminal ourdefaultsettingis Support TPportauto negotiation Enable or Disable TPportspeedselection 100M or 10M TPportduplexmodeselection Full or Half TPportflowcontrolselection Enable or Disable TPportlink LinkUp or LinkDown Fiberportflowcontrol backpressure Enable or Disable Fiberportduplexmode Full or Half Fiberportsignaldetect On or Off MCpowerstatus No...

Page 19: ...Chassis Chassis 0 3 MC 1 8 CPEMCStatus Statusofpower PowerOn or PowerOff Statusofreceivingopticalpower Normal or Fault Terminallinkstatus LinkUp or LinkDown MCstatus Normal or Fault Informing way for optical receiving power off Far End Fault Pattern or Maintenance Frame Statusofloopbacktest Normal or Fault Notificationoflinkstatusfortheterminal Support or NotSupport Terminallinkspeed 100M or 10M D...

Page 20: ...tton forthestatus 3 6 CPEMCControl Chassis Chassis 0 3 MC 1 8 CPEMCControl MCOptions ForwardingMode Store Forward or Cut Through or Repeater or Auto Change RemoteControl Disable or Enable LinkFaultPassThrough Disable or Enable MediaPort1 Type CurrentModel PortMode Auto or 10HD or 10FD or 100HD or 100FD FlowControl Disable or Enable MDIX Disable or Enable OutputRate Full or 25 or 50 or 75 InputRate...

Page 21: ... FaultPatten or MaintenanceFrame NOTE Afterconfigurationset needtopressthe Apply buttontosavethesetting 3 7 Loop backTest Chassis Chassis 0 3 MC 1 8 Loop backTest Status Final or Error Result OK or Messageforerror NOTE IfyouwishtoretestforLoopbackTestagain pleasepressthe Apply bottonfor themostupdatestatus 3 8 MCHardwareMonitor Chassis Chassis 0 3 MC 1 8 MCH WMonitor ...

Page 22: ...ts SupplyVoltage 3 3Volts Supplyvoltage 12Volts NOTE Under the normal condition suggest the tolerance for all SupplyVoltage should notexceed 10 4 Monitor 4 1 TotalCOMCStatus Monitor Chassis 0 3 TotalCOMCStatus Thissectiondivideto3differentManagedConverterChassiswithNo oneachChassisunit ...

Page 23: ...anual ThissectionyoucanseetheMCStatusforallMediaConverterinstalledintheChassis 4 2 TotalCPEMCAutoReport Monitor Chassis 0 3 TotalCPEMCAutoReport This section you can see the Terminal MC Auto Report for all Media Converter installed in theChassis ...

Page 24: ...tem 24 UserManual 4 3 TotalCPEMCStatus Monitor Chassis 0 3 TotalCPEMCStatus This section you can see the Terminal MC Status for all Media Converter installed in the Chassis 4 4 TotalLoopbackTest Monitor Chassis 0 3 TotalLoopbackTest ...

Page 25: ...ection you can see the Loopback Test Status for all Media Converter installed in the Chassis 4 5 TotalMCHardwareStatus Monitor Chassis 0 3 TotalMCHardwareStatus This section you can see the MC Hardware Status for all Media Converter installed in the Chassis ...

Page 26: ...ManagedMediaConverterChassisSystem 26 UserManual 4 6 ChassisMonitor Thissectionyoucanmonitorallthe0 3ManagedConverterChassisstatus 5 SNMPConfiguration ...

Page 27: ...ionforthesystemadministratorresponsibleformanaging system SystemLocation Descriptionofwhereyoursystemisphysicallylocated GetCommunity public private SetCommunity public private 6 Alarm 6 1 AlarmConfiguration Allowsanetworkadministratortodefinealarmevents 6 2 H WAlarmConfiguration ...

Page 28: ...ManagedMediaConverterChassisSystem 28 UserManual LowPowerLimit 0 100 HighTemperatureLimit C Suggestseton45 FanOperationTimeLimit Hours 1000Hoursormore 6 3 AlarmMail Trap ...

Page 29: ...o the configuredemailaddressthroughtheconfiguredmailserver 6 4 AlarmSNMP Trap SNMP enables network administrators to manage network performance find and solve network problems When SNMP Trap events are ON the device can send out trap messagesautomaticallytothetrapmanagerifconfigured 7 Save 7 1 ConfigurationofChassisManager ...

Page 30: ... sure column allchanged configuration for Chassis Manager willbesaved AndCancelwillbenosave 7 2 ConfigurationofallMC If press the save for configuration of all MC all previous changes of configuration will be startingtosaveuntilitshows Done NOTE NotetheN Aindicate NotApplicable ...

Page 31: ...ConfigurationofChassisManager If press OK for the Are you sure column all configuration for Chassis Manager will be reset to factory default And all configuration for Chassis Manager will not be reset to factory defaultifCancelwillbepressed 8 2 ConfigurationofallMC ...

Page 32: ...efault for configuration of all MC all configuration will be reset to factory default untilitshows Done NOTE NotetheN Aindicate NotApplicable 9 UpdateFirmware You can update the firmware of your system Normally this is done when a new version of firmwareisreleased ...

Page 33: ...Paircabling 10BASE T The IEEE 802 3 specification for Ethernet over Unshielded Twisted Pair UTP cabling auto negotiation A feature on a port that allows it to advertise its capabilities for speed duplex and flow control When connected to an end station that also supports auto negotiation thelinkcanselfdetectitsoptimumoperatingsetup stack Agroupofnetworkdevicesthatareintegratedtoformasinglelogicald...

Reviews: