8 MAINTENANCE AND SERVICE
158
TITAN VERSA Operations and Maintenance Manual
LACO Technologies
5.
Place leak detector on blocks to gain access to the bottom of the unit.
6.
Remove the four pump mounting bolts.
7.
Take the pump off for repair or maintenance.
Oil Change
–
Quick Method
CAUTION:
The User shall change the pump oil every 4300 hours
or 3-6 months (3 months for normal usage and 6 months for light
usage). Changing the pump oil regularly is the foundation of high
performing and long-lasting leak detection system. Failure to
change the pump oil regularly will cause decreased performance
and often leads to other failure points in the system.
Oil Type
–
LACO recommends the use of Elite-Z synthetic vacuum oil. Synthetic
vacuum pump oil ensures the pump runs cooler with longer intervals between
maintenance.
The user will need the following items to perform an oil change using the quick-change
method:
•
Oil Refill Cap
•
Oil drain line (In TITAN VERSA Spares and Tools Kit)
•
LVOEZ1015
–
Quick Fill Container
•
LVOFF1015
–
Flushing Fluid is recommended for contaminated, older, or heavily
used pumps.
1.
Is recommended the pump be a little hot to make the oil drain easy. Open the oil fill
port to drain the oil faster.
2.
Remove cap from top of rear cover.