5.1.7 Guider setup screen
This screen holds the parameters of the guiding
optics and mount, so “guider” in this context does
not mean the autoguider device. These values are
needed by some function that does not know
anything about the used system and giving the
values (approximately) helps them. Calibration is
such a function.
Obj. focus
: (
decimal
, 50 .. 60000 mm), profile
The focal length of the guider optics used with the Camera, in millimeters.
AG speed RA/DEC
: (
real
, 0.00 … 1.00), profile
The correction (autoguiding) speed (relative to sidereal rate) set in the mount’s
controller. Any non-standard rate can be set with 0.01 step size.
The RA speed can’t be set under 0.01x while for DEC it is allowed and means that
DEC speed always equals RA speed. (See the screenshot for the case.)
CCD binning
: (1x1, 2x2, 4x4, 6x6), profile
The used physical CCD binning size. Change its value with LEFT and RIGHT
buttons. CCD binning change takes place only if You altered the value and You
are leaving this screen with ESC. Then the device will pop up a question to ensure.
If the anser is Yes, the Camera changes binning mode immediately (current
autoguiding and star following must be stopped and lost).
Changing the values take effect immediately if no calibration is in use. If there is no
calibration data, the operation mode below is active:
Axis aligned, manual setup:
If You want to set up the autoguiding manually, You can skip using calibration. In this
case this screen’s values give information about the actual correction speeds. The RA
direction must be horizontally (X axis) and the DEC vertically (Y axis) aligned.
The actual RA speed (
spd
RA
*
) changes as a function of the object’s DEC coordinate
(
DEC
). This RA speed must be calculated and set up by the user manually. The formula is the
following:
spd
RA
*
=
spd
RA
·
cos(
DEC
)