background image

LACAVA 

6

How to Use

Place hands in the sensor field

2”-4” below the spout’s tip

Warm air blows until hands are removed  

or for 60 seconds of continuous operation

and then shuts down

Remove hands from sensing field 

for 3 seconds to repeat the cycle 

Maintenance

WARNING

DO NOT operate the hand dryer without the HEPA filter.  Operating the hand dryer without the 

LACAVA provided HEPA filter will void the product warranty. The H Class HEPA filter removes 99.99% 

of particles as small as 0.3 µm, including dust, mold spores and most bacteria from the airflow.  

It also ensures that the air flowing through the blower motor is clean and dust free.  Running the 

hand dryer without the filter may cause dust and small particles to be sucked into the blower, which 

may shorten the service life of the motor.  

A clogged-up filter reduces the air flow volume and puts unnecessary stress on the blower motor.

For relatively clean and dry environments, the HEPA filter should be replaced at least every 12 months.  

For moist or dusty environments, we recommend shorter replacement intervals, e.g. every 3 - 6 months.

        FILTER REPLACEMENT

1.

Unplug the power cord.

2.

Pull out the HEPA filter tray.  The tray is click-locked into place with small plastic tabs on the

body of the tray.  It might be tight when you try to pull it out.  Pry it out gently with flathead

screwdriver wiggling it  slightly side-to-side and up-and-down.  Do not use brute force.

3.

Remove the tray lid, replace the filter, put the lid back on, and insert the tray back into the

hand dryer body. There will be a distinctive “CLICK”when the tray is locked into place.

4.

Plug in the power cord, and the  hand dryer is back in service again.

tray cover

tray

CLICK!

Summary of Contents for ZOOM EX42-D1

Page 1: ...ary Revised 02 15 2023 LACAVA CHICAGO IL USA 773 637 9600 INFO LACAVA COM LACAVA COM EX42 SENR replacement sensor Power Supply Power supply Voltage 120V AC Frequency 50 60 Hz Power 1100W max Sensing d...

Page 2: ...ruction for commercial grade durability Includes spout flexible supply hose operating box and installation hardware Easy electric plug in power supply HEPA filter removes 99 99 of particles as small a...

Page 3: ...s planos proporcionados en este documento tienen el prop sito de dar al usuario una idea del producto y no est n hechos a escala Los tama os de pulgadas se redondean al m s cercano 1 16 4 100 32 1 1 4...

Page 4: ...glosamiento de Partes Note Please reference this sheet and the corresponding part number when requesting parts Nota Por favor referirse a esta pagina y la parte correspondiente cuando ordene partes 1...

Page 5: ...A dedicated 120 V AC 15A GFCI minimum outlet must be provided properly grounded and no more than 4 ft from the installation of the dryer assembly 2 If no GFCI outlet is provided contact a licensed ele...

Page 6: ...tion refer to ADA requirements a Mark the location of mouting screws and install the mounting bracket using the provided or suitable hardware b Hook the back of the hand dryer box onto the mounting br...

Page 7: ...which may shorten the service life of the motor A clogged up filter reduces the air flow volume and puts unnecessary stress on the blower motor For relatively clean and dry environments the HEPA filt...

Page 8: ...etergente suave es decir el jab n para lavar la vajilla para la limpieza Si se utiliza otro limpiador revise la etiqueta para asegurarse de que es seguro para el uso del material para su limpieza y si...