Installation Instructions/Instrucciones de Instalación
Warnings:
-Do not install the fixture facing a mirror-like surfaces or other electronic systems
operated by an infra-red sensor
-Space for installation so that the user hands should not interfere with the sensor
detection area while operating a nearby faucet or other objects
-The control box must be accessible after installation
1) A dedicated 120 V AC, 15A GFCI minimum outlet must be provided, properly grounded
and no more than 4 ft. from the installation of the dryer assembly.
2) If no GFCI outlet is provided, contact a licensed electrician to assure proper electrical
connections in accordance with local building codes.
3) Troubleshooting and internal maintenance must be performed by a qualified service
personnel.
IMPORTANT:
Min 10”
255
Installation Diagram
Mount and install components according to the diagram
Min 4”
100
Min 6”
152
Min 6”
152
FILTER
optional
soap
dispenser
optional
faucet
hand dryer
4
Max 48”
1220
Max 21”
533