background image

LACAVA 

4

Installation Instructions/Instrucciones de Instalación

1. Determine the location of the valve and install support 

    framing.

2. Position the valve in the wall and secure into place on the 

    support framing using the provided screws.  Refer to the 

    roughing-in dimensions on page 2 (or as marked on the

    plaster guards) for additional mounting information.

3. Install 1/2”NPT threaded copper adapters to the hot & cold 

    inlets, applying teflon tape to all threaded connections.  

    Then solder copper piping onto adapters and run to 

    designated water supply or outlet.

    Important! Take the following precautions if soldering copper 

    piping directly onto valve:

     a) Remove ALL components from the valve prior to soldering, 

          including plaster guards & cartridges.

     b) Wrap valve body with cold rag before soldering.  Take 

          special care not to overheat brass rough-in.

     c) Use copper piping only, do not attempt to solder steel 

          piping to valve.

     d) Flush the lines and reinstall all components after soldering.

4. Make sure both valves are in the off position and then turn on 

    the hot and cold water supplies and check for any leaks.

5. Remove the plaster guards and set up a bucket below the 

    spout opening to collect water.

6. Slowly open both valve stems and allow the water to flow for

    a minute.  

7. Close the valves and check for any leaks. Repair if necessary.

8. Reattach the plaster guards to the rough-in and finish the 

    surrounding wall.  To ensure proper fit, do not oversize the 

    holes for the spout and handles - use the plaster guards as

    a guide for correct diameter.

9. Remove plaster guards once the finished wall is complete.

H

C

Summary of Contents for Kubista 1424L

Page 1: ...te antes de la instalaci n LACAVA recomienda que este aparato sea instalado por un t cnico y no se hace responsable de los da os causados por una instalaci n incorrecta Es la responsabilidad del propi...

Page 2: ...no est n hechos a escala Los tama os de pulgadas se redondean al m s cercano 1 16 1424L 1424X 1 25 2 50 3 1 4 80 2 50 2 x M 1 2 7 7 8 200 14 5 8 370 9 230 1 3 4 3 3 4 45 95 50 2 50 2 1 1 8 3 1 8 30 80...

Page 3: ...cold Note Please reference this sheet and the corresponding part number when requesting parts Nota Por favor referirse a esta pagina y la parte correspondiente cuando ordene partes 1424L 1424X R1403...

Page 4: ...dering including plaster guards cartridges b Wrap valve body with cold rag before soldering Take special care not to overheat brass rough in c Use copper piping only do not attempt to solder steel pip...

Page 5: ...n their designated place on both esctucheons 13 Align the handles knobs or levers in the desired CLOSED position and place over the cartridge stems then align the handle bases with set screws on the b...

Page 6: ...o enjoy our products for many years to come Para mejores resultados por favor cuide des este producto de acuerdo con las siguientes instrucciones S lo utilice agua tibia y un detergente suave es decir...

Page 7: ...ACAVA LLC proporciona una Garant a Limitada de por Vida en sus grifos Esto garantiza que cualquier grifo instalado en una aplicaci n residencial no presentara defectos en el material o de fabricaci n...

Page 8: ...her it was our error If we verify it was our mistake we will promptly ship the missing item s to the purchaser by standard ground at our cost RETURN POLICIES If the product is not satisfactory for any...

Page 9: ...nte chofer de la compa a cualquier alteraci n visible en el empaque En el caso que falten art culos tambi n hay que informar a LACAVA y enviar todos los documentos relacionados con un plazo de 24 hora...

Reviews: