B
A
B
INSTALLER’S MANUAL
INSTALLER’S MANUAL
4
SITTING
GAS CONNECTION
CAUTION:
•
The buyer agrees to install the appliance in accordance with recognised best practices and the
regulations in force.
•
Any technical operation such as installation, repair or adjustment of the appliance must be carried
out by a qualified technician.
•
Do not lift the appliance by the front rail. Damages caused in this way are not covered by the
warranty.
•
If the appliance is to be installed against a wall or partition, or close to furniture or decorative
railing or skirting, these must be made of fireproof material. Otherwise, they must be lined with a
fireproof material. Special attention must be given to all fire prevention regulations. The flooring
in the room where the appliance is to be installed must be capable of withstanding temperatures
above 65°C.
•
Install a suitable extractor hood above the range cooker.
DELIVERY AND UNPACKING:
The appliance is delivered on a wooden pallet, packed with cardboard.
•
Unpack and check the appliance for damage upon receipt. In case of damage, mark the delivery
note accordingly, and within 48 hours notify the carrier in writing by registered mail with
acknowledgement of receipt.
•
To release the appliance from the pallet, use a 10 mm Allen key to remove the screws under the
pallet.
•
Remove the wooden pallet and put the appliance on the floor, taking care not to lift it by the front
rail.
Natural gas:
Since 1st July 1997, an automatic shut-off valve must be fitted to all new installation or whenever an
existing shut-off valve is replaced.
LPG (butane-propane):
Propane gas:
The installation must have a class-1 safety regulator.
Connect the appliance to the outlet of a 4 kg/h regulator. Recommended dual bottles to inlet of
regulator for correct operation of the appliance during prolonged periods at full capacity. Supply from
35 kg bottle or from tank is possible and recommended (connection to appliance using approved
LPG flexible hose with maximum length of 2 m).
Butane gas:
The connection must be made using a butane safety regulator fitted to the bottle (connection to
appliance using approved LPG flexible hose with maximum length of 2 m).
Connect the appliance to the outlet of a 2.6 kg/h regulator. Recommended dual bottles to inlet of
regulator for correct operation of the appliance during prolonged periods at full capacity.
CONNECTION:
•
The appliance is equipped with a Ø15/21 male connector
, 1/2" gas,
thread, to the back of the appliance.
•
For a correct supply, use an approved flexible connector of suitable
characteristics, such as a wire-reinforced flexible connector.
•
Once connected, check the supply pressure at the pressure port , to
the back of the appliance, in one of the ends of the gas inlet manifold.
•
Check the connection for leaks.
A
B
OPERATIONAL TESTS AND CHECKS:
Once connected, check that the burners operate correctly (hob and oven) and adjust as required.
CHECKING THE OPERATION OF THE HOB BURNERS:
•
Check that the appliance is connected to the electrical power supply. The electrical ignition works
if the appliance is connected to the electrical power supply.
•
Check that the gas shut-off valve is open.
Multicooker
Chargrill
Electric fryer
Gas burners
Induction
Ceramic Hob
Plancha
Summary of Contents for LAG 020 R