INSTALLER’S MANUAL
CHAMBERTIN – CHASSAGNE - FONTENAY
Page 13 of 47 – US –
Remove the pan supports and burners. Unscrew the screw(s)
C
on burner UF or T
(Figures 13 and 14). Pull and raise the top after having loosened the 2 screws
D
(Fig. 15), wedge the cooking surface.
A pressure regulator (fig. 16) is located in the right rear corner under the hob, to
gain access to the pressure regulator, remove the top.
The reversible cap is labelled either «LP» or «Nat» and is easily recognized by the raised center screw slot (for
Natural) or the center depth (for LP).
To change LP to Natural or vice versa, the seal screw in the regulator lid is unscrewed, reversed and reinstalled to
convert from one setting to another (Figures 17 and 18).