INSTALLER
’S MANUAL
SAULIEU – SAVIGNY - CITEAUX
Page 17 of 47 – US –
ELECTRICAL
It is hazardous to put the appliance into service without connecting it to suitable ground.
No liability can be accepted for accidents resulting
from non-compliance with this requirement or
incorrect grounding. Connect the equipotential
bonding terminal (
N
, Figure 30).
Before connection, check that the
:
Mains voltage is compatible with the appliance’s rated
voltage and thermal output.
Connection:
-
Use a 4-wire rated for 30 A 125 / 250 VAC, type SRD, SRDT, S, SO or ST.
-
Where local Codes do not permit grounding through neutral, use a 4-wire power supply cord or “pigtail” kit.
Cord must be agency approved for use with household ranges.
-
Remove access door
O
(Figure.31, gas oven range) or
P
(Figures 32 and 33, gas and electric range).
-
Remove cable clamp and loosen supply cord mounting screws on the terminal block.
-
Connect to terminal block in accordance with figure 35.
-
Secure the cable by means of cable clamp
(no provided), item
Q
(Figure 34).
-
Refit access door
THE APPLIANCE WHEN INSTALLED, MUST BE
ELECTRICALLY GROUNDED IN ACCORDANCE
WITH THE LOCAL CODES
OR The National Electrical
Code, ANSI/NFPA 70-1996 or latest edition
.
ALL WORK ON OR REPAIR OF AN APPLIANCE
MUST BE CARRIED OUT BY A QUALIFIED
INSTALLER.
IMPORTANT
N
Fig. 30
O
Fig 31
P
Fig 32