In case of use with a gas other than that for which the
appliance was initially set up, it is
crucial
to replace the
orifices and modify the adjustments as defined below.
TOP BURNERS:
Orifice:
Lift the air ring
E
. Replace the injectors
F
in accordance
with Table 3 and Figure 19 (Ø in 1/100 mm).
The side burner bodies are kept in place by a transversal
bar (
H
, fig. 21). In order to take them out, unscrew screws
I
(fig. 22) then
G
(fig. 20).
Note:
When one or more nozzles are changed, the sealing
ring should be changed as well (see gas circuit diagram).
Adjustment of primary air:
Refit the burner bodies and burner caps in their respective recesses,
adjust the air ring
F
of the burner in accordance with the Table 4
and Figure 19.
Note:
Normal flames are bluish green except for natural gas flames
which are violet.
Table 3
Burners
SR
R
I
UR
GAS
Pressure
Ø
Natural gas
6" WC
0.90
1.30
1.45 1.70
L.P. propane
10" WC
0.65
0.90
1.05 1.20
Clé de 3
Wrench 3 (
1
/
8
)
Fig. 20
G
I
Fig. 22
Clé de 7
Wrench 12 (
15
/
32
)
H
Fig. 21
Table 4
Burners
SF
F
I
UF
GAS
Pressure
Oppening in mm/ inches
Natural gas
6" WC
2,5 /
1
/
8
2,5 /
1
/
8
max
7 /
1
/
4
L.P. propane
10" WC 3,5 /
1
/
8
max
max
max
Clé de 12
Wrench 12 (
15
/
32
)
Fig. 19