Laboratory2, LTD
Logger stores from 32 to 48 latest events, as well as their time and date.
If the logger is turned on (see. 2.6 (i)) and voice recorder is switched off (except
emergency reset) logger is recorded to micro SD into the file INF_REG.TXT.
It is not recommended to use the logger continuously
since this reduces nonvolatile
memory resource of the voice recorder (it only affects work of the logger itself).
Brief description of the recorded events and the logger structure is given in Table 5.
Table 5. Description of logger tags and events.
Shorthand
Description
DEVICE_NUMBER
Voice recorder identification number
POWER_RESET
Reset by power failure
PIN_76_RESET
Processor hardware reset
PMMSWBOR
For official purposes
WAKE_UP_FROM_LPX.5
For official purposes
SECURITY_VIOLATION
For official purposes
SVSL
For official purposes
SVSH
For official purposes
SVML_OVP
For official purposes
SVMH_OVP
For official purposes
PMMSWPOR
For official purposes
WATCH_DOG_TIME_OUT
Looping / stop of the processor’s program due to
memory card or software failure
WDT_PSWRD_VIOLATION
For official purposes
FLASH_PSWRD_VIOL
For official purposes
PLL_UNLOCK
For official purposes
PERF_AREA_FETCH
For official purposes
PMM_PSWRD_RESET
Forced software reset (occurs when overwriting voice
recorder microprocessor program). Is called forcibly.
LOW_VOLTAGE_TURN_OFF
Low Battery - The recorder is turned off
Page
19
Version of 04.04.2019