BA_066 Rev 1J6 Mechanical thermometers 

Page 3/4 

Measuring devices where oil or grease residues in the measuring element are not 

permitted are marked on the scale with the oil can 

 icon.  

Measuring devices for use with oxygen are marked on the scale with the oil can 

 icon 

and the word “oxygen” directly below this. 

  

3.2  Options for gas expansion thermometer 

3.2.1 

Operation with capillary 

Route the capillary in a fixed and low-vibration manner. Note the specified maximum 
permissible ambient temperature on the data sheet. Exceeding the specified temperature 
limits can affect the measuring result. 

  

3.2.2 

Operation with contact sensor 

Fix the slightly U-shaped temperature probe to the pipe with steel strips. Insulate the 
measuring point and the temperature probe to the ambient temperature to ensure that the 
measuring result is not affected. With the “adjustable display“ option it is possible to rotate 
the housing around ±180° to the pipe after installation by loosening the screw connections, 
thereby achieving the optimum position. 

  

3.3  Electrical Connection 

Complete the mechanical installation before you connect the device electrically. Set up all 
electrical connections while the voltage supply is switched off. 

  

3.4  Adjusting of contacts 

Setting the contact can be done by using the adjustment lock in the centre of the sight 
glass. Just press down the separate or permanently mounted key (Figure  1) until the 
pointer of the lock catches the adjusting pin of the contact (Figure 2). 

 

Figure 1: Key 

 

Figure 2: Setting the contact 

The set pointer can be adjusted over the entire scale range. It must be ensured that the 
contact will be set in a clockwise direction only. If the contact is accidentally set behind the 
desired value, turn back the contact at least 5% below the desired value and make the 
setting again in a clockwise direction. 

The functionality and thus the switching reliability of the built-in switch contacts is 
guaranteed within the entire nominal range. Following valid standards though the accuracy 
stated in the data sheet is assured for switching points that are set between 10% and 90% 
of the nominal range only.  Operating the contact outside of the scale range is not 
permitted. 

You can find additional information on contacts in the document TA_039, available on our 
website at www.labom.com. 