LaBina PL-500 Control User Manual Download Page 11

www.PermanentLine.de

11

11

5th-Shader hygiene module (0,3 mm)

Needle

Art-No:

5th-Shader hygiene modules are bundled (5 x 0.3 
mm).

Practical tip:

 Depending on how often the skin is 

processed, soft to compact lines are feasible. We 
recommend the 5er-Shader modules for shading 
wide, almost transparent lines. 

PL-500 Control: E-0405

Application:

• 

Shading of eyebrow shape

• 

Eyebrow priming and full shading

 Shading of lip edges in case of narrow lips 

 Shading of full lips

3rd- and 5th-Slope hygiene module (0,4 mm)

Needle

Art-No:

In a sloping needle type, 3 or 5 needles are aligned
side-by-side at an angle of 32 degrees.

Practical tip:

 This needle combination developed 

by Dr. Linda Dixon requires special training. If you 
place the handpiece of the pigmentation instrument 
in a writing posture, the needles all pigment at the 
same depth. This allows a more efficient work.

PL-500 Control: E-0403S

PL-500 Control: E-0405S

Application:

  Recommended for lines and shading of eye-

brows and lips

Summary of Contents for PL-500 Control

Page 1: ...User s manual LaBina PL 500 Control www LaBina24 de...

Page 2: ...rator is obliged to comply with the principles of cleanliness and hygiene as well as to utilise so lely sterile disinfected materials Further information is provided in the chapter important hygiene a...

Page 3: ...nnot be guaranteed Sup plies must not be used after the expiration date The brackets and protective caps of the handpiece must also be cleaned and disinfected immediately before the treatment of every...

Page 4: ...signs of damage if the device does not run properly after a long period of storage beyond the mandatory temperature range in case of damages caused by improper transport The device should be transferr...

Page 5: ...5 N H F E K P M A K G B D Rear of the control unit Front of the control unit...

Page 6: ...sidues or scars could remain after the remo val During the first 4 to 6 weeks the intensity of the injected pigments is reduced to the permanent level This is usual as the epidermis upper skin layer i...

Page 7: ...stored in the original packaging Utilisation of pigments The module must be filled with 2 to 3 drops of colour Alternatively the tip of the module can be immersed into the colour for 2 to 3 seconds Th...

Page 8: ...www Labina24 de...

Page 9: ...Lip contour and fine inward lip shading Test point for allergy tests 1st Micro hygiene module 0 18 mm Needle Art No The needle diameter of the 1st Micro hygiene mo dule similar to the 1st Liner hygien...

Page 10: ...ely and are bundled closer to each other Practical tip Due to the closer bundling the 3rd Outline needle is not perceived to be as sharp as a 1st needle It enters the skin particularly well and traces...

Page 11: ...shading Shading of lip edges in case of narrow lips Shading of full lips 3rd and 5th Slope hygiene module 0 4 mm Needle Art No In a sloping needle type 3 or 5 needles are aligned side by side at an a...

Page 12: ...e of needles the customers experience less pain Ideal colour injection and shorter treatment time PL 500 Control E 0407 Application Broader lip contour Colour filling of the lips Areola and scars 9th...

Page 13: ...A make up that accompanies you regardless which weather...

Page 14: ...nd the device must never be directly soaked in a desinfectant agent as this may cause inner parts to corrode If a protective cap is used for storage purposes during a treatment the protective cap must...

Page 15: ...ciousness dizziness Particular caution is necessary in the following cases If the patient suffers from herpes simplex a pigmentation of the lips usually causes herpes labialis cold sores A prior consu...

Page 16: ...d oxidising acids e g peracetic acid lyes e g sodium hydroxide ammonia all substances with a pH level higher than 7 aromatic halogenated hydrocarbons e g phenol chloroform as well as acetone and petro...

Page 17: ...Control unit Rated voltage 15 V DC Power input 7 VA max Wall wart as stated on the type plate Level of protection 2 Operating conditions Ambient temperature 10 C to 35 C Relative humidity 30 to 75 17...

Page 18: ...device that is free of charge for the duration of the repair Distribution PERMANENT Line GmbH Co KG Complementary PERMANENT Line Schneider Kosmetik GmbH Mengeringh user Str 15 34454 Bad Arolsen Deutsc...

Reviews: