LaBina PL-500 Control User Manual Download Page 10

10

Ihre Fachpraxis für Permanent Make-up 

10

Needle combination of hygiene modules

3rd-Liner hygiene module (0,3 mm)

Needle

Art-No:

The bundle with classical 3rd hygiene module round  
needles is 0.65 mm wide (with a diameter of each 
0.3 mm).

Practical tip:

 The needles cause a slightly wider 

line. In order to create a soft start and a tapered pha-
se out of the eyeliner we recommend the 3rd-Outline 
module.

PL-500 Control: E-0403

Application:

• 

Shading of eyebrow shape

•  

Soft, slightly wider lines at the lash line

• 

Suitable for broader eyeliners

3rd-Outline hygiene module (0,25 mm)

Needle

Art-No:

The needles of the 3rd-Outline hygiene have a dia-
meter of only 0.25 mm. Compared to the 3rd need-
le type they are grinded more delicately and are 
bundled closer to each other.

Practical tip:

 Due to the closer bundling the 3rd-

Outline needle is not perceived to be as sharp as 
a 1st needle. It enters the skin particularly well and 
traces a fine line while at the same time allowing a 
denser colour injection.

PL-500 Control: E-0430

Application:

 Lash thickening on the lower eyelid

  Especially suitable for a fine rise and phase out 

on the broad upper eyeliner

  Also very popular for thin lip contours

4th-Flat hygiene module (0,4 mm)

Needle

Art-No:

In the 4th-Flat hygiene module, the needles are ho-
rizontally positioned in one line.

Practical tip:

 If a broader line is desired, make sure 

that the needle is traced exactly at a right angle to 
the line and the handpiece is held vertically to the 
skin to enable all needle tips to inject the colour at 
the same depth.

PL-500 Control: E-0404

Application:

 Recommended for wide lines 

 Ideal for shading of larger areas

Summary of Contents for PL-500 Control

Page 1: ...User s manual LaBina PL 500 Control www LaBina24 de...

Page 2: ...rator is obliged to comply with the principles of cleanliness and hygiene as well as to utilise so lely sterile disinfected materials Further information is provided in the chapter important hygiene a...

Page 3: ...nnot be guaranteed Sup plies must not be used after the expiration date The brackets and protective caps of the handpiece must also be cleaned and disinfected immediately before the treatment of every...

Page 4: ...signs of damage if the device does not run properly after a long period of storage beyond the mandatory temperature range in case of damages caused by improper transport The device should be transferr...

Page 5: ...5 N H F E K P M A K G B D Rear of the control unit Front of the control unit...

Page 6: ...sidues or scars could remain after the remo val During the first 4 to 6 weeks the intensity of the injected pigments is reduced to the permanent level This is usual as the epidermis upper skin layer i...

Page 7: ...stored in the original packaging Utilisation of pigments The module must be filled with 2 to 3 drops of colour Alternatively the tip of the module can be immersed into the colour for 2 to 3 seconds Th...

Page 8: ...www Labina24 de...

Page 9: ...Lip contour and fine inward lip shading Test point for allergy tests 1st Micro hygiene module 0 18 mm Needle Art No The needle diameter of the 1st Micro hygiene mo dule similar to the 1st Liner hygien...

Page 10: ...ely and are bundled closer to each other Practical tip Due to the closer bundling the 3rd Outline needle is not perceived to be as sharp as a 1st needle It enters the skin particularly well and traces...

Page 11: ...shading Shading of lip edges in case of narrow lips Shading of full lips 3rd and 5th Slope hygiene module 0 4 mm Needle Art No In a sloping needle type 3 or 5 needles are aligned side by side at an a...

Page 12: ...e of needles the customers experience less pain Ideal colour injection and shorter treatment time PL 500 Control E 0407 Application Broader lip contour Colour filling of the lips Areola and scars 9th...

Page 13: ...A make up that accompanies you regardless which weather...

Page 14: ...nd the device must never be directly soaked in a desinfectant agent as this may cause inner parts to corrode If a protective cap is used for storage purposes during a treatment the protective cap must...

Page 15: ...ciousness dizziness Particular caution is necessary in the following cases If the patient suffers from herpes simplex a pigmentation of the lips usually causes herpes labialis cold sores A prior consu...

Page 16: ...d oxidising acids e g peracetic acid lyes e g sodium hydroxide ammonia all substances with a pH level higher than 7 aromatic halogenated hydrocarbons e g phenol chloroform as well as acetone and petro...

Page 17: ...Control unit Rated voltage 15 V DC Power input 7 VA max Wall wart as stated on the type plate Level of protection 2 Operating conditions Ambient temperature 10 C to 35 C Relative humidity 30 to 75 17...

Page 18: ...device that is free of charge for the duration of the repair Distribution PERMANENT Line GmbH Co KG Complementary PERMANENT Line Schneider Kosmetik GmbH Mengeringh user Str 15 34454 Bad Arolsen Deutsc...

Reviews: