Chapter 3: Getting Started

 

Product Service 1-800-522-7658

 

Unpacking Your RapidVap Vertex 
Evaporator 

 
Carefully unpack your RapidVap Vertex Evaporator and inspect it for damage 
that may have occurred in transit.  If your RapidVap Vertex Evaporator is 
damaged, notify the delivery carrier immediately and retain the entire shipment 
intact for inspection by the carrier. 
 

DO NOT RETURN GOODS WITHOUT THE PRIOR 
AUTHORIZATION OF LABCONCO.  UNAUTHORIZED 
RETURNS WILL NOT BE ACCEPTED. 

 
 

IF YOUR RAPIDVAP VERTEX EVAPORATOR WAS 
DAMAGED IN TRANSIT, YOU MUST FILE A CLAIM 
DIRECTLY WITH THE FREIGHT CARRIER.  LABCONCO 
CORPORATION AND ITS DEALERS ARE NOT 
RESPONSIBLE FOR SHIPPING DAMAGES. 

 
Do not discard the carton or packing material for your RapidVap Vertex 
Evaporator until you have checked all of the components and installed and 
tested the RapidVap Vertex Evaporator. 

 

RapidVap Vertex Evaporator 
Components 

 
Locate the model of RapidVap Vertex Evaporator you received in the 
following table.  Verify that the components listed are present and undamaged. 
 

Catalog # 

Description 

7320020 

RapidVap Vertex Evaporator – 115V  

Plus the Following: 
Part # 

Component Description 

7913100 

Exhaust Hose 

1966000 

Clamp 

1334500 

Power Cord NEMA 5-15P  

7324400 

User’s Manual 

1533301 

Tubing 

 

The United 
States 
Interstate 
Commerce 
Commission 
rules require 
that claims be 
filed with the 
delivery 
carrier within 
fifteen (15) 
days of 
delivery. 

 

 

Summary of Contents for RapidVap 73200 Series

Page 1: ...RapidVap Vertex Evaporator Models 73200 Series ...

Page 2: ... of 7 30 a m and 5 30 p m Central Standard Time Part 7324400 Rev C ECO L627 Warranty Labconco Corporation provides a warranty to the original buyer for the repair or replacement of parts and reasonable labor as a result of normal and proper use of the equipment with compatible chemicals Broken glassware and maintenance items such as filters gaskets light bulbs finishes and lubrication are not warr...

Page 3: ... Your RapidVap Vertex Evaporator 8 Sample Block 8 Nitrogen Gas Connection 9 Exhaust Port 9 Electrical Connection 10 Chemical Attack on RapidVap Vertex Evaporator Components 10 Solvent Safety Precautions 11 CHAPTER 4 USING YOUR RAPIDVAP VERTEX EVAPORATOR 13 Planning 14 Loading Glassware into the RapidVap Vertex Evaporator 14 RapidVap Vertex Evaporator Controls 14 Operating the RapidVap Vertex Evapo...

Page 4: ...PPENDIX A RAPIDVAP VERTEX EVAPORATOR COMPONENTS 25 APPENDIX B RAPIDVAP VERTEX EVAPORATOR DIMENSIONS 28 APPENDIX C RAPIDVAP VERTEX EVAPORATOR SPECIFICATIONS 29 Evaporation Rates 31 APPENDIX D RAPIDVAP VERTEX EVAPORATOR ACCESSORIES 32 ...

Page 5: ...sample thereby increasing the evaporation rate A precisely controlled amount of thermal energy can be supplied to the sample to heat it Finally a stream of nitrogen or dry gas is directed downward onto the surface of the sample This reduces the partial pressure directly over the liquid to speed evaporation and helps remove the solvent as it evaporates In summary the RapidVap Vertex Evaporator perf...

Page 6: ...ted in the margins provide suggestions reminders and references Critical information is presented in boldface type in paragraphs that are preceded by the exclamation icon Failure to comply with the information following an exclamation icon may result in injury to the user or permanent damage to your RapidVap Vertex Evaporator Important information is presented in capitalized type in paragraphs tha...

Page 7: ...t the area is level and of solid construction In addition an exhaust means must be provided and a source of nitrogen or dry gas must be available An electrical source must be located near the installation site Carefully read this chapter to learn the electrical supply requirements the exhaust requirements the nitrogen supply requirements Refer to Appendix C RapidVap Vertex Evaporator Specification...

Page 8: ... The RapidVap Vertex Evaporator must be located within a fume hood if hazardous or flammable solvents are used In all cases regardless of the solvent used it is recommended that the exhaust hose is vented into a fume hood or other laboratory ventilation device Nitrogen Supply Requirements The 1 4 I D hose on the rear of the RapidVap Vertex Evaporator should be attached to a regulated source of nit...

Page 9: ...Read this chapter to learn how to unpack and move your RapidVap Vertex Evaporator set up your RapidVap Vertex Evaporator connect the nitrogen source to your RapidVap Vertex Evaporator connect the electrical supply source to your RapidVap Vertex Evaporator properly exhaust your RapidVap Vertex Evaporator solvent safety precautions The RapidVap Vertex Evaporator weighs over 35 lbs 16 Kg The carton a...

Page 10: ...ONCO CORPORATION AND ITS DEALERS ARE NOT RESPONSIBLE FOR SHIPPING DAMAGES Do not discard the carton or packing material for your RapidVap Vertex Evaporator until you have checked all of the components and installed and tested the RapidVap Vertex Evaporator RapidVap Vertex Evaporator Components Locate the model of RapidVap Vertex Evaporator you received in the following table Verify that the compon...

Page 11: ...iption 7913100 Exhaust Hose 1966000 Clamp 1332700 Power Cord CHI 10P 7324400 User s Manual 1533301 Tubing Catalog Description 7320040 RapidVap Vertex Evaporator 230V US Plus the Following Part Component Description 7913100 Exhaust Hose 1966000 Clamp 1338000 Power Cord NEMA 6 15P 7324400 User s Manual 1533301 Tubing Since users preference of sample size varies the sample holding block is not includ...

Page 12: ... in the holes in the block Select the appropriate block to fit the vials that will be used Make certain that the bottom of the chamber is clean and free of debris The sample block slides in on the two guides on the front and MUST rest securely on the bottom Make certain that the small 21 dia temperature sensor hole is in the upper left hand corner Placing the block in the chamber improperly will e...

Page 13: ...f the hose to user supplied nitrogen supply THE NITROGEN SUPPLY PRESSURE MUST NEVER BE ALLOWED TO EXCEED 80 PSI 345 KPA Exhaust Port If the RapidVap Vertex Evaporator is not located in a fume hood attach one end of the two inch diameter venting hose that is supplied with the RapidVap Vertex Evaporator to the exhaust port on the rear of the unit Clamp securely Route the other end to a fume hood or ...

Page 14: ...to degradation are as follows C Moderate Degradation Questionable Use D Severe Degradation Infrequent use recommended immediate thorough cleaning required Acids Bases Solvents COMPONENT MATERIAL Acetic Acid 20 Boric Acid Formic Acid Hydrobromic Acid 20 Hydrochloric Acid 20 Nitric Acid 20 Sulfuric Acid 10 Trifluoroacetic Acid TFA Ammonium Hydroxide Potassium Hydroxide Acetone Acetonitrile Chlorofor...

Page 15: ...ractices It has been designed for use with compounds as described in the United States National Electrical Code Class I Group D The block that holds the sample tubes may be programmed to run as hot as 100 C however the heater element may normally run at 135 C A thermal fuse limits the heater to a maximum temperature of 152 C It is important that the solvents used are compatible with these temperat...

Page 16: ...sconnect power from outlet before beginning service operations Do not damage internal wiring or other components while service panels are removed If internal wiring or components are damaged do not restore power contact Labconco s Product Service Department immediately Wear all required Personnel Protective Equipment PPE during service operations At a minimum this includes eye protection breathing...

Page 17: ...rator Read this chapter to learn how to set operating parameters operate the controls properly select and position glassware inside your RapidVap Vertex Evaporator understand the display interrupt a cycle after it has begun Do not use the RapidVap Vertex Evaporator in a manner not specified by the manufacturer refer to Appendix C RapidVap Vertex Evaporator Specifications The electrical protection ...

Page 18: ...ocol it may be helpful to make a trial run that is void of the sample you are attempting to concentrate Select the size of the sample tube so it is compatible with the block Tubes should not be loose in the block Blocks are available with holes for various size tubes Loading Glassware Into the RapidVap Vertex Evaporator There are 5 control valves that control nitrogen to the 5 horizontal rows of n...

Page 19: ...clockwise to increase pressure counter clockwise to decrease the pressure The operating pressure is displayed on the knob Once the pressure is set push the regulator knob in and press Stop The pressure can be adjusted at any time during the run Also note that opening or closing any of the Nitrogen Control Valves without adjusting the pressure will change the flow rate at each nozzle The flow rate ...

Page 20: ... or TIME The display will show Ten different programs may be stored and then later recalled Press PROG or TEMP or TIME and the word will start to flash Press Up or Down to change the value Another word may be selected and the value under the word may be changed by pressing Up or Down Press either Run to begin the run or press Back to return to the opening display If TIME is set to ON the program w...

Page 21: ... press SET TEMP to set the pre heat temperature The display will show The SET TEMP will flash Then press Up or Down to adjust the block temperature In this example 52 is the temperature of the sample block 51 is the upper block or sample temperature The heater will heat the block and maintain it at the set temperature Press Stop to turn the heater off and to return to the opening display BLOCK SAM...

Page 22: ...mple 52 indicates the sample block temperature 51 indicates the upper block temperature or sample temperature and 124 indicates the time remaining for this programmed run Press Pause to temporarily halt the run The word Pause will be replaced with Re Start which when pressed will continue the run from the point where it was paused Press Stop to halt the run entirely The display will show the openi...

Page 23: ...es to be used during the run Then press run to open the gas supply valve Pull out the regulator knob and turn the knob until the desired pressure is displayed in the center of the knob Evaporation rates will be higher at increased pressure However splashing of the sample may occur It is advisable to perform a set up run void of analytes to determine the optimal pressure for the tube and sample siz...

Page 24: ... it is important to press the Stop button prior to pressing Run This will reset the timer back to the programmed set point Without pressing the program set point button the time will not be reset and will continue to count down from the time at which it was stopped Interrupting a Cycle After it Has Begun At any time during a run the cycle may be stopped by pressing the Pause button This shuts off ...

Page 25: ... The rubber components on the RapidVap Vertex Evaporator may eventually deteriorate and require replacement The effective life of rubber parts depends upon both their usage and the surrounding environment Check all rubber hoses and gaskets and replace any that show signs of hardening permanent set or deterioration 2 Using a soft cloth sponge or chamois and a mild non abrasive soap or detergent cle...

Page 26: ... Unit not connected to electrical power Connect unit to proper electrical receptacle Circuit breaker blown Correct electrical problem and reset circuit breaker by pressing button Lid open Close lid Sample odor in lab Vent hose exhausting into lab area Redirect hose to fume hood Inoperable blower Replace blower Solvent in bottom of chamber Gas pressure too high Reduce pressure Poor recovery rates S...

Page 27: ...nish gas supply Heater inoperable Contact Labconco No gas flow Gas depleted Install new supply of gas Sample position not activated Activate position per operating instructions Nozzle clogged Unplug nozzle with fine wire Valve inoperable Contact Labconco Gas flows continuously Valve inoperable Contact Labconco Control inoperable Contact Labconco ...

Page 28: ...Chapter 6 Troubleshooting Product Service 1 800 522 7658 24 ...

Page 29: ... AP P V VE ER RT TE EX X E EV VA AP PO OR RA AT TO OR R C CO OM MP PO ON NE EN NT TS S The following pages list components that are available for your RapidVap Vertex Evaporator The parts shown are the most common replacement parts If other parts are required contact Product Service ...

Page 30: ...sor Lower 4 1 7325100 Over Temperature Cut Out 5 2 1544600 Inlet Fitting 6A 1 7322200 Control Valve 115V 6B 1 7322201 Control Valve 230V 7 1 3823803 Power Supply 8A 1 1289310 Circuit Breaker 10A 115V 8B 2 1289306 Circuit Breaker 6A 230V 9 1 1302300 Power Switch 10 1 7321400 Label Control Panel 11 1 7321900 Pressure Regulator 12 5 7322500 Valve Toggle 13 1 7323100 PCB 14 1 7323000 LCD 15 1 7355301 ...

Page 31: ...Appendix A RapidVap Vertex Evaporator Components Product Service 1 800 522 7658 27 ...

Page 32: ...Product Service 1 800 522 7658 28 A AP PP PE EN ND DI IX X B B R RA AP PI ID DV VA AP P V VE ER RT TE EX X E EV VA AP PO OR RA AT TO OR R D DI IM ME EN NS SI IO ON NS S ...

Page 33: ...pidVap Vertex Evaporator Vacuum models 7320030 7320035 7320037 7320040 4A Frequency all models 50 60 Hz Phase Single Heater power 900 watts Environmental Conditions Indoor use only Maximum altitude 6562 feet 2000 meters Ambient temperature range 41 to 104 F 5 to 40 C Maximum relative humidity 80 for temperatures up to 88 F 31 C decreasing linearly to 50 relative humidity at 104 F 40 C Main supply ...

Page 34: ...nt Occasionally however a temporary conductivity caused by condensation must be expected in accordance with IEC 664 Nitrogen Consumption Gas flow RapidVap Vertex Evaporator with 10 active nozzles 0 74 SCFM 15 psi 21 L min 103 KPA 1 00 SCFM 24 psi 28 3 L min 165 KPA Gas flow RapidVap Vertex Evaporator with 50 active nozzles 4 5 SCFM 20 psi 127 L min 138 KPA 5 00 SCFM 24 psi 141 5 L min 165 KPA ...

Page 35: ... 2 80 24 6 20 x 150 10 10 52 37 42 Water 12 x 75 10 2 45 24 125 12 x 75 10 2 60 24 80 12 x 75 10 2 80 24 40 12 x 75 10 2 100 24 25 20 X 150 10 4 100 24 60 20 X 150 50 4 100 24 64 Toluene 12 x 75 10 2 35 16 24 12 x 75 10 2 45 16 18 12 x 75 10 2 60 16 13 12 x 75 10 2 80 16 9 Methylene 12 x 75 10 2 35 20 8 Chloride 12 x 75 10 2 45 22 7 20 x 150 10 10 38 37 22 Hexane 20 x 150 10 10 52 37 11 Ethyl Acet...

Page 36: ...s Holds 50 7321200 Block 12 mm dia x 75 mm long tubes Holds 50 7321300 Block 13 mm dia x 100 mm long tubes Holds 50 7321600 Block 16 mm dia x 125 mm long tubes Holds 50 7322000 Block 20 mm dia x 150 mm long tubes Holds 50 7322800 Block 28 mm dia x 95 mm long tubes Holds 18 7322801 Block 28 mm dia x 140 mm long tubes Holds 18 7322300 Block 17 mm dia x 125 mm long tubes Holds 50 7321601 Block 16 mm ...

Reviews: