background image

 

 

       Product Service 1-800-522-7658, International 816-333-8811 

 
 
 
 
 
 
 
 
 

C

C

H

H

A

A

P

P

T

T

E

E

R

R

 

 

3

3

 

 

G

G

E

E

T

T

T

T

I

I

N

N

G

G

 

 

S

S

T

T

A

A

R

R

T

T

E

E

D

D

 

 

 

 

Now that the site for your Storage Cabinet is properly 
prepared, you are ready to unpack, inspect, and install, 
the Storage Cabinet.  Read this chapter to learn how to: 
 

 

Unpack and move the Storage Cabinet. 

 

Set up the Storage Cabinet – Acid, Solvent, 
Standard Base, and Vacuum Pump. 

 

Properly level the Storage Cabinet. 

 

Properly install the accessory work surface. 

 

Attach the filler panel for additional 
aesthetics. 

 

Properly vent the Storage Cabinet. 

 

Properly ground the Solvent Cabinet. 

 

Connect the electrical supply source to the 
Vacuum Pump Cabinet. 

 
Depending upon which model of Storage Cabinet you 
are installing, you will need common hand tools, 
including a Phillips head screwdriver, a flat blade 
screwdriver, a ¾" open end wrench, and pliers to 
complete the instructions in this chapter. 
 
 
 
 
 
 
 
 

Summary of Contents for Protector Series

Page 1: ...200 9901200 9902200 9903200 9904200 9900300 9901300 9902300 9903300 9904300 9900400 9901400 9902400 9903400 9904400 9900500 9901500 9904500 9900600 9901600 9900700 9900800 9905000 9906000 9907000 9905...

Page 2: ...00 a m and 6 00 p m Central Standard Time Part 9918500 Rev E ECO E394 Warranty Labconco provides a warranty on all parts and factory workmanship The warranty includes areas of defective material and w...

Page 3: ...14 Vacuum Pump Storage Cabinets 16 Installation 18 Cabinet Leveling All Cabinets 18 Vent Installation 19 Acid Storage Cabinet 19 Solvent Storage Cabinet 20 Filler Panel All Cabinets 21 SpillStopper W...

Page 4: ...APPENDIX B CABINET REPLACEMENT PARTS 35 APPENDIX C CABINET ACCESSORIES 36 APPENDIX D QUICK REFERENCE STORAGE CABINETS 39 DECLARATION OF CONFORMITY 40...

Page 5: ...Solvent Storage Cabinets are designed to efficiently store flammable materials and includes a 1 1 2 double wall construction for fire protection Protector Standard Base Storage Cabinets are utilized f...

Page 6: ...ry Vent connections are located on the back wall of the cabinet and can be used at the discretion of the customer The vent connection on the Solvent Storage Cabinet is supplied with a closure plug on...

Page 7: ...3 Getting Started contains the information you need to properly unpack inspect and install the Storage Cabinet Chapter 4 Using Your Storage Cabinet discusses the normal operation of the Storage Cabin...

Page 8: ...amation icon Failure to comply with the information following an exclamation icon may result in injury to the user or permanent damage to the Storage Cabinet Important information is presented in capi...

Page 9: ...torage Cabinet You must be certain that the area is level and of solid construction In addition your Storage Cabinet should be adjacent to a vent connection to allow for venting to the exterior of the...

Page 10: ...Cabinet Acid Solvent Standard Base and Vacuum Pump Properly level the Storage Cabinet Properly install the accessory work surface Attach the filler panel for additional aesthetics Properly vent the St...

Page 11: ...STORAGE CABINET WAS DAMAGED IN TRANSIT YOU MUST FILE A CLAIM DIRECTLY WITH THE FREIGHT CARRIER LABCONCO CORPORATION AND ITS DEALERS ARE NOT RESPONSIBLE FOR SHIPPING DAMAGE Do not discard the carton o...

Page 12: ...t Left Hinged 9905000 24 ADA Acid Cabinet Right Hinged 9905100 18 ADA Acid Cabinet Right Hinged 9905200 24 ADA Acid Cabinet Left Hinged 9905300 18 ADA Acid Cabinet Left Hinged 9902000 48 Manual Closin...

Page 13: ...Interior Depth Protector XL Fume Hood 1928300 Leveling Feet 4 Different filler panel depths are available refer to Appendix C Storage Cabinet Accessories for filler panel selection If you do not rece...

Page 14: ...ng non locking doors The doors are 18 gauge epoxy coated steel and feature a strike and latch assembly to hold them in position once closed 3 Vent Connection Cabinet features two vent connections on t...

Page 15: ...11 Product Service 1 800 522 7658 International 816 333 8811 Chapter 3 Getting Started Protector Standard Base Storage Cabinet...

Page 16: ...Vent Kit the cabinet may be vented to the fume hood or directly outside Instructions for venting can be found on page 22 For Acid Vent Kit accessory see page 43 4 Optional Accessory Shelf Features 16...

Page 17: ...13 Product Service 1 800 522 7658 International 816 333 8811 Chapter 3 Getting Started Protector Acid Storage Cabinet...

Page 18: ...eel shelf features fully welded corners to hold spills and epoxy coated to provide a chemical resistant surface The shelf supports inside the cabinet allows for height adjustment 5 Vent Connection Two...

Page 19: ...15 Product Service 1 800 522 7658 International 816 333 8811 Chapter 3 Getting Started Protector Solvent Storage Cabinet...

Page 20: ...g door The door is of 18 gauge epoxy coated steel and features a strike and latch assembly to hold it in position once closed 3 Vent Connection Cabinet features two vent connections on the back wall o...

Page 21: ...17 Product Service 1 800 522 7658 International 816 333 8811 Chapter 3 Getting Started Protector Vacuum Pump Storage Cabinet...

Page 22: ...have been packaged separately and must be installed on the bottom of the cabinet before installation Each leveling foot is independently adjustable by turning it by means of a crescent wrench undernea...

Page 23: ...to use The lower vent connection should be used for heavier than air vapors and the upper vent connection should be used for lighter than air vapors to obtain the best results within the cabinet struc...

Page 24: ...back wall should be used for lighter than air vapors to obtain the best fume removal within the cabinet The cabinet vent connections are designed to accept 2 diameter threaded metal pipe material whic...

Page 25: ...o close off the plumbing access Attach the filler panel angle directly to the back wall of the cabinet structure using the four 8 sheet metal screws that hold the back panel in position Next attach th...

Page 26: ...o the cabinet It is held in place both by its own weight and the weight of the fume hood and other equipment on top of it Align the work surface on top of the cabinet before making plumbing or electri...

Page 27: ...national 816 333 8811 Chapter 3 Getting Started SpillStopper Work Surface Installation Detail Dimensions Shown in Inches Hood Depth B Hood Internal Depth D Filler Panel Depth E Work Surface Depth 33 1...

Page 28: ...net Use the grounding screw located in the lower right hand corner on the back panel of your solvent storage cabinet to properly ground the cabinet structure Remove the grounding screw and attach a gr...

Page 29: ...Cabinet Remove the four shelf brackets included with the cabinet s leveling feet and place one bracket in each of the shelf positions located on the interior walls of the cabinet Make sure that the sh...

Page 30: ...asing linearly to 50 relative humidity at 104 F 40 C Main supply voltage fluctuations not to exceed 10 of the nominal voltage Transient overvoltages according to Installation Categories II Overvoltage...

Page 31: ...it in a safe manner Normal Operation Although the Storage Cabinet is engineered to maintain the optimum in operator safety caution should always be used while working with it Good general housekeepin...

Page 32: ...ld a fire occur Do not store flammable material in excess of the individual Solvent Storage Cabinet rating Ratings are located on the nameplate of each Solvent Storage Cabinet Do not block either vent...

Page 33: ...5 M MA AI IN NT TA AI IN NI IN NG G Y YO OU UR R S ST TO OR RA AG GE E C CA AB BI IN NE ET TS S Under normal conditions the Storage Cabinet requires little maintenance The following maintenance schedu...

Page 34: ...8811 A AP PP PE EN ND DI IX X A A S ST TO OR RA AG GE E C CA AB BI IN NE ET T D DI IM ME EN NS SI IO ON NS S The following drawings provide dimensions for the Standard Base Cabinet Acid Storage Cabin...

Page 35: ...31 Product Service 1 800 522 7658 International 816 333 8811 Appendix A Dimensions Protector Standard Base Cabinet...

Page 36: ...32 Product Service 1 800 522 7658 International 816 333 8811 Appendix A Dimensions Protector Acid Storage Cabinet...

Page 37: ...33 Product Service 1 800 522 7658 International 816 333 8811 Appendix A Dimensions Protector Solvent Storage Cabinet...

Page 38: ...34 Product Service 1 800 522 7658 International 816 333 8811 Appendix A Dimensions Protector Vacuum Pump Cabinet...

Page 39: ...ary Catch Door Latch All but Solvent 1930600 Shelf Support Clip Solvent Solvent Only 9921200 48 Adjusting Solvent Shelf Solvent Only 9921201 36 Adjusting Solvent Shelf Solvent Only 9921202 30 Adjustin...

Page 40: ...ed connector locknut flexible tubing and vent extension Vent kit is used for venting Acid Storage Cabinets through Spillstopper worksurface and into the fume hood Shipping weight 5 lbs 2 3 kg Shelf Ki...

Page 41: ...6 Work Surface Only 42 Depth 9727517 8 Work Surface Only 42 Depth 9727518 10 Work Surface Only 42 Depth Two Piece 9727519 12 Work Surface Only 42 Depth Three Piece 9727520 16 Work Surface Only 42 Dep...

Page 42: ...302 Panel Filler 36 for Interior depth Protector XL Fume Hood 9920303 Panel Filler ADA 24 for Interior depth Protector XL Fume Hood 9920304 Panel Filler ADA 30 for Interior depth Protector XL Fume Hoo...

Page 43: ...g Automatic Latching Doors 9903200 24 w Self Closing Automatic Latching Doors 9903300 9903400 24 ADA 9906000 9906100 9905000 9905200 24 ADA w Self Closing Doors 9906200 9906300 18 ADA 9905100 9905300...

Page 44: ...et 9901000 thru 9901600 Acid Storage Cabinet 9905000 thru 9905300 ADA Acid Storage Cabinet 9902000 thru 9902400 Solvent Storage Cabinet 9903000 thru 9903400 Self Closing Solvent Storage Cabinet 990600...

Reviews: