Chapter 4: Performance Features & Safety Precautions
Product Service 1-800-522-7658
23
Original instructions
11.
All hoods are factory-prepared for up to 7 service fixtures
. Additional
fixtures are available only as a factory special. Liner hole drilling is
required to add another fixture in the field.
12.
One duplex electrical receptacle
is mounted on the right corner post.
Receptacles are factory-wired to hood single point junction box.
Additional electrical receptacles are available as factory or field installed.
13.
Type 304 Stainless Steel interior liner
is seamless with coved interior
corners and integral work surface.
14.
Accessory Guardian™ Digital Airflow Monitor
or
Guardian Jr.
Monitor
continuously monitors face velocity. An audio/visual alarm alerts
the user to low airflow conditions. The right corner post is factory
prepared to accommodate the Guardian Monitor (sold separately).
15.
Optional Energy-Reducing A-Style Combination Sash Models.
These
combination sashes allow the operator to use the hood with sashes either
half open vertically or horizontally to conserve energy. Optional sash stops
prevent raising the vertical sash above the half-open and fully closed
positions unless manually defeated by the operator.
16.
Outside frame of epoxy-coated steel and galvanized steel
is durable and
corrosion resistant.
17.
Exhaust connection
. The hood features 11" (11.00" OD pipe) Type 304
Stainless Steel exhaust connections sized to allow for a minimum static
pressure loss through the hood structure while providing a good transport
velocity through the exhaust system.
18.
Solid hardboard support
provided to support the integral Type 316
Stainless Steel bottom.
19.
Optional Ceiling Enclosure Kits
are available for a decorative facade
between the hood and the ceiling.
20.
Optional Sash Stops
provide a means of controlling the operating height
of the sash.
21.
Built-in Upper Bypass.
The Radioisotope Hood includes an upper bypass
block which proves to be useful when working with heat in digestions.
22.
CAUTION –
Current rating of receptacle is specified in
Appendix D
.
AVERTIR –
Classification des prises de courant est spécifié dans l’Annexe D.
23.
CAUTION –
See Appendix C and D for complete current rating.
AVERTIR –
Voir Annexe C et D pour la classification complete du courant.
24.
CAUTION –
Flammable Gas.
AVERTIR –
Gaz Inflammable.