Set-up and Operation

Auto Standby / Power-up

LUCIA amplifiers do not have a power switch. The amplifier will turn on 
automatically when AC power is connected to the unit; it will go into 
standby mode if no signal is present at any input for 20 minutes. When in 
standby, the amplifier will power up in two seconds when a signal above 
the preset threshold (-54 dBu default) is present at any channel input. 

GPIO Configuration: Two Ouput 

Low Impedance Models

Default functionality is as described below for General Purpose Inputs and 
Output (GPIO). 

Remote volume control 

– The default functionality for the GPI is 

independent control of output volume; please note that this control is in 
series with the control of from the front panel. There are two ways to do 
this: 

 

Connect a GPO from a control device that outputs 0 – 3.3 V 

 – Pins 5 and 6 connect to an internal relay to provide 

amplifier fault indication. The relay is closed when the amplifier is on and 
operating normally. The relay opens if a fault in either the output channel(s) 
or in the power supply interrupts normal operation of one or both channels.

Optional GPIO modes

 – The Matrix models allow other GPIO functions to be 

enabled by applying changes to the amplifier firmware. See the full Operation 
Manual for more information.

 

for control. Their grounds also need to be connected; see full  

 

Operational Manual for further instructions. 

 

Connect a remote volume control potentiometer per channel to  

 

pins 1 through 4 of the GPIO connector as shown below. 

 

(The Vcc voltage output is 3.3 V). 

 – Connect an external contact closure to Ground 

and GPI2 as shown in the diagram following. Wake-up happens within 0.5 
s after contact closure.

– Pins 5 and 6 connect to an internal relay to provide 

amplifier fault indication. The relay is closed when the amplifier is on 
and operating normally. The relay opens if a fault in either the output 
channel(s) or in the power supply interrupts normal operation of one or 
both channels. 

Optional GPIO modes

 – The Matrix models allow other GPIO functions 

to be enabled by applying changes to the amplifier firmware. See the full 
Operation Manual for more information. 

Individual volume control

R

R

Common volume control

R

GPIO Configuration: Mono High-Impedance

The Default functionality is as described below for General Purpose Inputs 
and Output (GPIO).

Remote volume control 

– Connect a remote volume control 

potentiometer to Ground, GPI1 and Vcc as shown in the diagram 
following.  Volume control is after input mixing. (The Vcc voltage output 
is 3.3 V).

R

DSP/Matrix Configuration

The LUCIA models include a mix matrix and a comprehensive suite 
of DSP features. In nearly all applications for this type of amplifier, the 
included features eliminate the need for an external mixer or processing 
unit. Also, the default DSP and matrix configuration allows “out of the 
box” installation with no further configuration required for many typical 
applications.

Default preset 

– The default matrix and DSP configuration is as follows 

for the M models:

SPEAKER 1 = IN 1; volume attenuated with GPI 1 (and front knob)
SPEAKER 2 = IN 2; volume attenuated with GPI 2 (and front knob) 
Out 3 = In 1 (-6 dB) + In 2 (-6 dB); volume attenuated with GPI 1 
Out 4 = In 1 (-6 dB) + In 2 (-6 dB); volume is not affected by GPI

Software download and installation

 – Very intuitive configuration 

software is available that allows selection of which preset to use 
(optimized for different loudspeakers) and what dynamics processing to 
use. This application is available for free download from  
www.labgruppen.com/support. 

USB connection

 – A USB connection is provided for firmware updates 

and downloading presets to the LUCIA. For complete information please 
refer to the full Operation Manual.

– Please refer to the full Operation Manual for 

detailed information on custom configuration of DSP functions using the 
LUCIA configuration application.

Third-party control 

 – The LUCIA models have a built-in RS-232 serial 

interface, enabling third-party products to control and monitor LUCIA. 
For more information on RS-232 serial interface usage, please refer to the 
“LUCIA Serial Dongle – RS-232 Quick Start Guide”, which can be downloaded 
from http://labgruppen.com/support/download-quick-start-guide 

Summary of Contents for LUCIA 120/1-70

Page 1: ...LUCIA Compact installation amplifiers Rev 4 0 1 Item no QSG LUCIA Quick Start Guide LUCIA 60 2 LUCIA 120 2 LUCIA 240 2 LUCIA 60 2M LUCIA 120 2M LUCIA 240 2M LUCIA 60 1 70 LUCIA 120 1 70 LUCIA 240 1 70...

Page 2: ...2...

Page 3: ...3 Contents 4 English Quick start guide 9 14 19 Fran ais Guide de prise en main 24 Deutsch Das Wichtigste in K rze 29 Espa ol Gu a de Inicio R pido...

Page 4: ...features offered in the LUCIA and a brief explanation of use with the default DSP preset which is appropriate for many typical applications It also includes instructions on downloading the Windows bas...

Page 5: ...iate means to ensure similar load condition as specified above To attach the wall brackets B to your amplifier please use the supplied 3 mm Torx machine screws Rack shelf mounting The amplifier can be...

Page 6: ...rrect polarity and ground terminations are shown on the rear panel 2 Unbalanced audio inputs 1 2 Connect unbalanced inputs e g local video screen output CD player to the RCA phono inputs Note Balanced...

Page 7: ...r transformer Consequently taps should be set to twice the desired power 4 GPIO Remote connector Connect external control and status monitoring devices using the six pole Euroblock connector See GPIO...

Page 8: ...allow other GPIO functions to be enabled by applying changes to the amplifier firmware See the full Operation Manual for more information Individual volume control R R Common volume control R GPIO Co...

Page 9: ...9 1 FCC 2000m FCC 15 B B ICES 003...

Page 10: ...no 42 CEE 7 page VII SR section 107 2 D1 IEC 83 page C4 BS 1363 of 198413A Lab gruppen B 3 4 3 5 25 4 5 3 Molly E22412 UL CA60065 B 3 3 A 4 20 10 20 Lab Gruppen L ab Gruppen LUCIA Lab Gruppen LUCIA LU...

Page 11: ...11 LED 3 3 1 2 1 2 3 Euroblock 1 2 GPIO Euroblock USB B USB LUCIA 60 2M 120 2M 240 2M 3 4 3 Euroblock 3 Euroblock LUCIA60 2 120 2 240 2 60 2M 120 2M 240 2M...

Page 12: ...12 7 LUCIA60 1 70 120 1 70 240 1 70 1 8 9 3 5 7 4 6 2 1 2 3 Euroblock 1 2 CD RCA GPIO 6 Euroblock GPIO 70V 100V 100V 100V 3dB 70V USB DSP DSP B USB USB IEC 9 80 Hz 50 Hz...

Page 13: ...B USB LUCIA LUCIA RS 232 LUCIA RS 232 LUCIA Serial Dongle RS 232 Quick Start Guide http labgruppen com support download quick start guide LUCIA DSP GPIO GPIO GPIO GPI1 Vcc Vcc 3 3V R GPI2 0 5 Pins 5 6...

Page 14: ...14 1 2 3 4 5 6 7 8 9 10 11 12 13 14...

Page 15: ...125 V US UL817 and CSA C22 2 no 42 220 230 V EUROPE CEE 7 page VII SR section 107 2 D1 IEC 83 page C4 240 V UK BS 1363 of 1984 Specification for 13 A fused plugs and switched and unswitched socket ou...

Page 16: ...16 1 2 3 4 1 8 3 5 7 4 9 6 2 LUCIA 60 2 120 2 240 2 60 2M 120 2M 240 2M...

Page 17: ...17 1 8 9 3 5 7 4 6 2...

Page 18: ...18 R R R R 5 6 GPIO Matrix GPIO LUCIA RS 232 LUCIA RS 232 http labgruppen com support download quick start guide LUCIA Serial Dongle RS 232 Quick Start Guide LUCIA RS 232...

Page 19: ...e et la configuration dans des installations complexes Ce guide de prise en main pr sente galement les fonctions de DSP offertes par les LUCIA et une br ve explication de l empl v a i o ec le pr r gla...

Page 20: ...es surfaces veuillez vous assurer que la m thode de fixation est adapt e au mat riau du mur Assurez vous galement que les supports seront fix s au moyen d une visserie appropri e afin de respecter les...

Page 21: ...triques par ex la sortie d un cran vid o local un lecteur de CD aux entr es RCA cinch phono Remarque les entr es sym triques et asym triques sont en parall le une seule paire d entr es doit donc tre...

Page 22: ...urveillance d tat au moyen de ce connecteur Euroblock 6 points Voir Configuration GPIO dans la section Configuration et fonctionnement qui suit 5 Port USB Se connecte un ordinateur externe pour t l ch...

Page 23: ...let pour plus d informations Commande des volumes individuels R R Commande du volume g n ral R Configuration GPIO mod les une sortie Les fonctionnalit s sont d crites ci dessous avec leurs entr es et...

Page 24: ...f r typische Anwendungen Ausf hrliche Informationen zu Wartung und K hlungsbedarf zur Garantie und zur Konfiguration f r komplexere Anwendungen entnehmen Sie bitte dem Betriebshandbuch Operation Manu...

Page 25: ...ka F r die Montage an anderen Oberfl chen nicht Trockenbau stellen Sie bitte sicher dass Sie ein f r den jeweiligen Baustoff geeignetes Montageverfahren nutzen Achten Sie au erdem darauf dass die Wink...

Page 26: ...gnalquellen zum Beispiel Video monitore oder CD Player an Anmerkung Die symmetrischen und unsym metrischen Eing nge sind parallel geschaltet Es sollte zu jedem Zeitpunkt nur an jeweils ein Eingangspaa...

Page 27: ...lte der gew nschten Leistung erfolgen 4 GPIO Fernbedienungs Anschluss Schlie en Sie externe Steue rungs und Status berwachungsger te an diesen sechspoligen Eurob lock Anschluss an Siehe hierzu auch de...

Page 28: ...on Manual Individuelle Pegelsteuerung R R Gemeinsame Pegelsteuerung R GPIO Konfiguration Modelle m einem Ausgang Die Standard Funktionalit t f r GPIO General purpose input output wird nachfolgend besc...

Page 29: ...ucciones completo para ver todos los detalles acerca del uso y mantenimiento de este aparato necesidades de ventilaci n garant a y configuraci n en instalaciones complejas Este manual de puesta en mar...

Page 30: ...acuerdo al UL CA60065 Para montaje en otras superficies aseg rese de que el m todo de montaje sea el adecuado para el material de la pared Aseg rese tambi n de fijar las abrazaderas de la forma corre...

Page 31: ...s 1 y 2 Conecte entradas no balanceadas p e la salida de una pantalla de v deo reproductor de CD a estas tomas RCA Nota Las entradas balanceadas y no balanceadas van en paralelo solo puede conectar un...

Page 32: ...e conseguir esto Conecte un GPO desde un dispositivo de control que emita 0 3 3V para el control Tambi n debe conectar las tomas de tierra vea m s detalles en el Manual de instrucciones completo Conec...

Page 33: ...procesado de se al externos Adem s la configuraci n por defecto de la matriz y el DSP permiten una instalaci n tal cual sale del embalaje de la unidad sin la necesidad de ning n otro ajuste para la ma...

Page 34: ...34 Notes...

Page 35: ...35 Notes...

Page 36: ...Auto Load SenseTM are trademarks of Lab gruppen AB All other trademarks remain the property of their respective owners Copyright 2015 MUSIC Group Innovation Sweden AB All rights reserved labgruppen co...

Reviews: