Lab.gruppen iP Series IP 1350 Brochure Download Page 7

iP 2100

iP 1350

iP 900

iP 450

iP 1150Q

Max output power

1) 

Four channels

EIA at 1 kHz and 1 % THD

per channel

425 W

300 W

200 W

110 W

130 W

per channel

700 W

500 W

320 W

160 W

200 W

per channel

1050W

700 W

470 W

200 W

270 W

bridged

1400 W

1000 W

600 W

300 W

400 W

bridged

2100 W

1400 W

900 W

400 W

540 W

Max output voltage

8 ohms load

58 V

rms

49 V

rms

39 V

rms

30 V

rms

32 V

rms

Peak voltage, no load

92 V

77 V

63 V

50 V

51 V

Distortion etc.

THD 20 Hz – 20 kHz
and 1 W to full power

0.05 %

0.03 %

0.02 %

0.05 %

0.05 %

THD at 1 kHz and 1 dB below clipping

0.005 %

0.005 %

0.005 %

0.03 %

0.01 %

DIM 30 at 3 dB below clipping

0.005 %

0.005 %

0.008 %

0.02%

0.008 %

Hum and noise 

–105 dB

–110 dB

–105 dB

–105 dB

–105 dB

Channel separation 

at 10 kHz

70 dB

70 dB

70 dB

70 dB

70 dB

Output impedance

30 m

30 m

30 m

30 m

30 m

Slew rate 

45 V/µs

45 V/µs

30 V/µs

25 V/µs

30 V/µs

Inputs

Gain selectable

20, 23, 26, 29,

20, 23, 26, 29

20, 23, 26, 29,

20, 23, 26, 29

32

32, 35, 38, 41

32, 35, 38, 41

32, 35, 38, 41

32, 35, 38, 41

Impedance 20 

k

20 k

20 k

20 k

20 k

Common mode rejection

50 dB

50 dB

50 dB

50 dB

50 dB

Front panel

Gain controls

31 pos detent

31 pos detent

31 pos detent

31 pos detent

31 pos detent

Indicators per channel:
Protect Yes

Yes

Yes

Yes

Yes

Clip

Yes

Yes

Yes

Yes

Yes

Signal present

– 40 dB

– 40 dB

– 40 dB

– 25 dB

– 40 dB

Rear panel

Input connectors

Neutrik Combo+

Neutrik Combo+

Neutrik Combo+

Neutrik Combo+

Neutrik Combo

3 pin Phoenix

3 pin Phoenix

3 pin Phoenix

3 pin Phoenix

Clip limiters

On/Off, each ch.

On/Off, each ch.

On/Off, each ch.

On/Off, each ch.

On/Off, each ch.

Power

Operation voltage, 230V/115V

130–260V/65–135V

130–260V/65–135V

130–260V/65–135V

130–260V/65–135V

130–260V/65–135V

Soft Start

Yes

Yes

No

No

No

Peak inrush current

20 A

20 A

10 A

20 A

70 A

Full output power at 4 ohms, 230V/115V

230V/115V

230V/115V

230V/115V

230V/115V

230V/115V

Minimum start-up voltage, 230V/115V

190V/95V

190V/95V

180/95V

NA

180/95V

230 V or 115 V versions

Yes

Yes

Yes

Yes

Yes

Current draw at 4 

and 230V/115V

Idle, no load at output

0.8 A

rms

0.6 A

rms

0.5 A

rms

0.1 A

rms

0.6 A

rms

1/8 of full power (-9 dB)

5.2 A

rms

3.5 A

rms

2.3 A

rms

0.8 A

rms

2.9 A

rms

1/3 of full power (-5 dB)

8.0 A

rms

5.5 A

rms

3.7 A

rms

1.5 A

rms

4.5 A

rms

At full power (0 dB) at 1 kHz 1 % THD

13.0 A

rms

9.4 A

rms

6.5 A

rms

3.3 A

rms

7.9 A

rms

Dimensions 

Width 

483 mm (19

"

)

483 mm (19

"

)

483 mm (19

"

)

483 mm (19

"

)

483 mm (19

"

)

Height

88 mm (3.5

"

)

88 mm (3.5

"

)

88 mm (3.5

"

)

44 mm (1.75

"

)

88 mm(3.5

"

)

Depth

325 mm (12.8

"

)

325 mm (12.8

"

)

325 mm (12.8

"

)

280 mm (11.0

"

325 mm (12.8

"

)

Weight

18.0 kg (39.6 lbs)

15.0 kg (33 lbs)

12.5 kg (27.5 lbs)

7.5 kg (17 lbs)

13.3 kg (29 lbs)

Approvals: CE 

Emission: EN 55 103-1, E3
Immunity: EN 55 103-2, E3, with S/N below 1 % at normal operation level
Safety: EN 60 065, class 1,        THX approval except iP 450

Technical Data.

7

1) Specifications measured with 230 V AC

Lab.gruppen reserve the right to alter functions or the specifications without prior notice.

Summary of Contents for iP Series IP 1350

Page 1: ...d Specialist So are our iP Series power amplifiers You need reliable amp technology plus that special little extra for comfort and performance A perfect combination for perfectionists 450 2100 W Lates...

Page 2: ...ries power amplifiers are the cream of their class Supreme performers Quality symbols Eternal work horses in any professional sound system Make yourself depending and be depend able no matter if you n...

Page 3: ...and mains fuse Amplifiers get hot Wrong Because there is Lab gruppen Sure heat is gene rally a problem because it stresses the components and has led elsewhere to shows ending early Some amplifiers e...

Page 4: ...ruppen love to share their gained know ledge with you Gain structure Gain Knowledge The simple things get often overlooked Why We don t know So we decided to make it really simple for you to connect o...

Page 5: ...ely wide window of operation where mains voltage is con cerned however in the case of the mains voltage being below or above the window of opera tion the amplifier will mute itself thanks to its AC Ma...

Page 6: ...tions stereo 8 ohms 4 ohms 2 ohms EIA at 1 kHz and 1 THD 200 W 320 W 470 W Intercooler speed controlled fans Multiple Position Gain XLR Phoenix input connector Soft start Weight 12 5 kg 27 5 lbs Dimen...

Page 7: ...Neutrik Combo Neutrik Combo Neutrik Combo Neutrik Combo 3 pin Phoenix 3 pin Phoenix 3 pin Phoenix 3 pin Phoenix Clip limiters On Off each ch On Off each ch On Off each ch On Off each ch On Off each ch...

Page 8: ...Lab gruppen AB Gullregnsv gen 16 SE 434 44 Kungsbacka Sweden Tel 46 300 56 28 00 Fax 46 300 56 28 99 info labgruppen com www labgruppen com...

Reviews: