Lab.gruppen iP Series IP 1350 Brochure Download Page 5

5

When working with a Lab.gruppen iP
Series amplifier, all necessary protection
is already built in to prevent damage to
your amp and as much as possible to
your speakers as well. All protection cir-
cuitry has an automatic reset, so you do
not need to worry, or take any action.

THERMAL PROTECTION

Should you – against all odds – manage
to overheat the amp, the Thermal
Protection will mute the affected amp
channel until it has cooled down.

ALS

®

Our smart ALS® is an ‘Adaptive
Limiting System’ that monitors the out-
put signal continuously to limit its cur-
rent dynamically.

If for any reason distortion above 1 %

THD appears between input and output
of an amp channel, a Clip Limiter will
reduce the signal proportionally. You
only need to make sure that the input
signal is ‘clean’. The Clip Limiter is the
only protection that you can manually
defeat using recessed switches on the
rear.

VHF PROTECTION

To protect your HF drivers
from any oscillation, the VHF
Protection will mute the amp
once a signal above 12 kHz is
present at the amp’s output at
full output power for more
than five seconds.

AC MAINS VOLTAGE 
PROTECTION

iP Series amps have an extrem-
ely wide window of operation
where mains voltage is con-
cerned; however, in the case of
the mains voltage being below
or above the window of opera-
tion, the amplifier will mute
itself thanks to its AC Mains
Voltage Protection.

Naturally, all Lab.gruppen

amps are DC and Short Circuit
protected.

Average life is risky

enough. Audio is safe with
Lab.gruppen.

High-frequency drivers are well protected
by the automatic VHF-protection.

Recessed bypass switch per
channel for the clip limiter.

Indicators for VHF and temperature
protection.

Protect Yourself?

We do not make receivers or trans-
mitters. From the early days that we
were making Switch Mode amplifiers,
we always complied with any emission 

and immunity requirements,
including today’s tough
European Electro-Magnetic
Compatibility directive
(EMC).

With Lab.gruppen iP

Series amplifiers you do not
need to fear any interference
with RF equipment. If you
hear strange voices please

check elsewhere.

You’re not alone. When it comes

to power amps, Lab.gruppen is on
your side.

  

Hz

50

100

200

500

1000

dB

-120

-110

-100

-90

-80

-70

-60

-50

-40

iP 2100 Magnetic fields 50 Hz – 1.4 kHz

RF emission from an iP 2100 …

Lab.gruppen’s EMC test facilities. 8,000 volts
are being “shot” with this gun for testing!

The very finest test equipment is made in-house;
here is a coil for measuring the hum field.

We only make Amplifiers.

Summary of Contents for iP Series IP 1350

Page 1: ...d Specialist So are our iP Series power amplifiers You need reliable amp technology plus that special little extra for comfort and performance A perfect combination for perfectionists 450 2100 W Lates...

Page 2: ...ries power amplifiers are the cream of their class Supreme performers Quality symbols Eternal work horses in any professional sound system Make yourself depending and be depend able no matter if you n...

Page 3: ...and mains fuse Amplifiers get hot Wrong Because there is Lab gruppen Sure heat is gene rally a problem because it stresses the components and has led elsewhere to shows ending early Some amplifiers e...

Page 4: ...ruppen love to share their gained know ledge with you Gain structure Gain Knowledge The simple things get often overlooked Why We don t know So we decided to make it really simple for you to connect o...

Page 5: ...ely wide window of operation where mains voltage is con cerned however in the case of the mains voltage being below or above the window of opera tion the amplifier will mute itself thanks to its AC Ma...

Page 6: ...tions stereo 8 ohms 4 ohms 2 ohms EIA at 1 kHz and 1 THD 200 W 320 W 470 W Intercooler speed controlled fans Multiple Position Gain XLR Phoenix input connector Soft start Weight 12 5 kg 27 5 lbs Dimen...

Page 7: ...Neutrik Combo Neutrik Combo Neutrik Combo Neutrik Combo 3 pin Phoenix 3 pin Phoenix 3 pin Phoenix 3 pin Phoenix Clip limiters On Off each ch On Off each ch On Off each ch On Off each ch On Off each ch...

Page 8: ...Lab gruppen AB Gullregnsv gen 16 SE 434 44 Kungsbacka Sweden Tel 46 300 56 28 00 Fax 46 300 56 28 99 info labgruppen com www labgruppen com...

Reviews: