Installation 

1

Transport

ing

 the Skid System

Unless otherwise requested, 

Laars 

Skid Systems are transported within the continental United States and

Canada via commercial truck.

 

Each skid system will be accompanied by document packaging that includes the installation instructions. 
Store skid system documents for reference.

 

NOTICE! Check the load ratings on equipment intended to be used to transport the system 

Remove the shipping crate top and sides.

Locate the forklift tubes on the skid 

system and lift for transport

NOTICE! During transit, transport close to the 
ground. Use all standard safety measures and 
precautions prior to and during transit. 

NOTICE! Use caution when transporting. 
Always use proper lifting techniques. Weight 
distribution is unbalanced and the product is 
susceptible to tipping which will result in 
damage to the product. 

Secure heater by bolting each leg to the 

floor using 3/8” (10mm) anchor bolts. 

5

Summary of Contents for N Series

Page 1: ...s Tankless Heater Models LCTEC216 2x LCTEN108 LCTEC252 2x LCTEN126 LCTEC288 2x LCTEN144 Voltage options for models 600V Three Phase 480V Three Phase 415V Three Phase 400V Three Phase 380V Three Phase...

Page 2: ...shed and then completely turned off before beginning installation Debris in supply lines can cause valves to malfunction CAUTION Hot pipes DO NOT touch May cause burns NOTICE These heaters DO NOT prov...

Page 3: ...Specific Requirements The N Series Skid C Series can be used in many different applications that require custom tuning for specific applications to maximize performance of the heater For use in a re c...

Page 4: ...freeze protected from the factory and on site installation of freeze protection is the sites responsibility NOTICE For heaters with ENHT freeze protection option s If the heater is stored where the t...

Page 5: ...pment intended to be used to transport the system Remove the shipping crate top and sides Locate the forklift tubes on the skid system and lift for transport NOTICE During transit transport close to t...

Page 6: ...for service and maintenance of the cabinet enclosure and a minimum of 48 1219mm above the top of the cabinet enclosure is needed Verify skid system is in final installation location Secure the base to...

Page 7: ...ate or Ball Type Valves Elbows nipples and fittings as needed Components included in the N Series Skid C Series Systems are different from the standard N Series Heater See dimensional drawings for ref...

Page 8: ...Installation 8 68 1734 69 1759 80 2035 81 2065 80 2035 81 2065 N Series Skid C Series Dimensions 3 Plumbing Installation Cont...

Page 9: ...ly following the union No valve or restriction is between the relief valve and the system or the relief valve and drain Shutoff valve is installed after pressure and temperature relief valve on outlet...

Page 10: ...aars com Technical Support Website Email 603 335 6300 or Toll Free 800 900 9276 www laars com For field service please contact your professional installer or local Laars sales representative United St...

Reviews: