28
Mascot LX Service Manual
N05 - Domestic hot water sensor not present
This may mean that the sensor is disconnected or not working. If this condition
continues, the controller will present a Lockout message.
• Check for an input on terminals 9 and 10 on the low voltage terminal. If there
is no input, check the domestic hot water temperature sensor and replace it if
necessary. See Section B6.
N06 - Outdoor temperature sensor not present
This may mean that the sensor is disconnected or not working. If this condition
continues, the controller will operate at a setpoint of 140°F or the value of Installer
Parameter P62 (High Setpoint for Heat Curve), whichever is lower.
• Check for an input on terminals 1 and 2 on the low voltage terminal.
• If there is no input, check the outdoor temperature sensor and replace it if nec
-
essary. See Section B7.
A3
cont.
Notification Codes (continued)