Adjustment of the automatic closing time: this is only adjustable on the Master operator:
Setting the forces:
Force exerted by the leaf (leaves) during opening. Represents the percentage of force exerted,
other than that saved during autoconfiguration (and subsequent updates)
before the obstacle alarm is activated.
This parameter is automatically configured during autoconfiguration.
CAUTION: This has a direct effect on the force of impact:
check that the configured value complies with current safety regulations (*).
Install anti-crush safety devices if necessary (**).
Force of leaf/
Open Force
leaves during
opening [%]
Force exerted by the leaf/leaves during closing. Represents the percentage of force exerted,
other than that saved during autoconfiguration (and subsequent updates)
before the obstacle alarm is activated.
This parameter is automatically configured during autoconfiguration.
Close
Force of leaf/
leaves during
force
closing [%]
CAUTION: This has a direct effect on the force of impact:
check that the configured value complies with current safety regulations (*).
Install anti-crush safety devices if necessary (**).
Force exerted by the leaf/leaves during opening at slow speed*.
Represents the percentage of force exerted, other than that saved during autoconfiguration
(and subsequent updates) before the obstacle alarm is activated.
This parameter is automatically configured during autoconfiguration.
Slow open
Force of leaf/
leaves during
force
slow opening [%]
CAUTION: This has a direct effect on the force of impact:
check that the configured value complies with current safety regulations (*).
Install anti-crush safety devices if necessary (**).
Represents the percentage of force exerted, other than that saved during autoconfiguration
(and subsequent updates) before the obstacle alarm is activated.
This parameter is automatically configured during autoconfiguration.
Slow close
Force of leaf/
leaves during
force
slow closing [%]
CAUTION: This has a direct effect on the force of impact:
check that the configured value complies with current safety regulations (*).
Install anti-crush safety devices if necessary (**).
Activation/Deactivation of automatic closing:
Activates the cell, during closing only:
It is recommended to add an additional 10%, once the autotest has been completed.