24
V
– CARE AND MAINTENANCE
Important
: always unplug your wine dispenser before cleaning of performing
maintenance.
Never use harsh cleansers or scouring pads to clean any part of the wine dispenser.
Cleaning
To clean the bottle fixer and solenoid valve :
▪
Fill a bottle with clean warm water and place the bottle-fixer into the bottle.
▪
Press and hold the
button to dispense the warm water. Press portion
button
5 times and then hold it until the display shows “CL” and flashes,
the automatic clean will start.
▪
Continue to dispense and flush the system until dry gas comes from the spout.
VI
– TROUBLESHOOTING
Problem
Causes
Solution
Nothing appears
on the display.
▪
No power supply
▪
You did not press the switch
▪
Malfunction at the outlet
▪
No electricity at plug
▪
Make sure the device is
plugged in
▪
Press the switch
▪
Change the plug
▪
Find the reason why
there is no electricity
The compressor
works but there is
no refrigeration
.
▪
Check that there is no
refrigerant leak
▪
Have a refill of refrigerant
by the SAV
Refrigeration is too
weak.
▪
Low voltage
▪
Unsuitable room temperature,
reduced refrigeration effects
▪
Leak in the refrigerant circuit
▪
Fans do not work
▪
Increase the tension
▪
Place the device at least
150mm from the wall
▪
Detect the leak and make a
refill of refrigerant
▪
Replace the fan