27
EOLO - COMFORT 80
EN
13.6
"NO IGNITION" ALARM
"ACTIVE ALARM" "AL 5 - NO IGNITION": if the temperature is not sufficient for ignition.
•
Reset the error with P4 key. The stove carries out a "FINAL CLEANING" step and then "OFF" appears.
•
Check the type of failure as shown on
.
•
Clean the burning pot and start the stove up again pressing P4 key.
13.7
"NO PELLET" ALARM
If the fume probe detects a temperature at the exhaust which is lower than the minimum threshold, the display
shows "ACTIVE ALARM" "AL 6 - NO PELLET"
•
Reset the error with P4. The stove carries out a "FINAL CLEANING" step and then "OFF" appears.
•
Full the hopper.
•
Clean the fire pot and start the stove up again pressing P4 key.
13.8
"THERMAL SAFETY" ALARM
In the hopper is installed a manual reset thermostat which activates if the range of temperature in the tank
exceeds the allowed limits. This avoids that the pellet inside the hopper can burn because of overheating.
"ACTIVE ALARM" "AL 7 - THERMAL SAFETY": the thermostat disconnect power supply to the auger.
•
Reset the error with P4 key. The stove carries out a "FINAL CLEANING" step and then "OFF" appears.
•
Check the type of failure as shown on
.
•
Unscrew the black lid, press the button and screw again the protection lid.
•
After having cleaned the burning pot, start the stove up again pressing P4 key.
13.9
"FAILURE DEPRESS" ALARM
To the boiler is connected a pressostat which checks the depression.
"ACTIVE ALARM" "AL 8 - FAILURE DEPRESS": the pressostat stops the power supply to the auger.
•
Reset the error with P4 key. The stove carries out a "FINAL CLEANING" step and then "OFF" appears.
•
Check the type of failure as shown on
.
•
Clean the burning pot and start the stove up again pressing P4 key.
13.10
"OPEN DOOR" ALARM
On the lower part of the fire door is installed a microswitch which detects the opening.
"ACTIVE ALARM" "AL 9 - OPEN DOOR": it means that the fire door is not correctly closed.
•
Reset the error pressing P4 key. The stove carries out a "FINAL CLEANING" and "OFF" appears.
•
Check the type of failure as shown on
.
•
Clean the burning pot and start the stove up again pressing P4 key.
14
MAINTEINANCE
14.1
INTRODUCTION
For a long working life of the stove, have a periodic cleaning of the stove as described in the following paragrafs.
•
Fume outlet pipes (fume c chimney flue + chimney pot) must always be cleaned, scrubbed and
checked by an authorized technician in compliance with local regulations, with the instructions of the
manufacturer and those of your insurance company.
•
If there are no local regulations and no instruction from your insurance company, it is necessary to have your
fume pipe, chimney flue and chimney pot cleaned at least once a year.
•
It is also necessary to have the combustion chamber, motors and fans cleaned and to have the gaskets and
the electronical elements checked at least once a year.
All these operations must be planned in time with your Autorized Technical Assistance
Service.
•
After a long ineffective time, before turning on the stove check if there are obstructions in the fume exhaust.
•
If the stove had been using continuously and intensely, the whole system (chimney included), must be
cleaned and checked more frequently.
•
In case of replacement of damaged pieces please ask for the original spare part at the Autorized Retailer.
14.2
BURNING POT AND ASH TRAY CLEANING
Every 2 days the burning pot and the ash tray must be cleaned.
•
Open the door.