EN
10
Espresso machine installation, strada ep
1) Fill water reservoir with potable water.
Once the espresso machine has been
unpackaged, placed on a hard surface.
Remove the drain tray and slide the water
reservoir until the water reservoir fill cover
is accessible. Remove the cover and fill
water reservoir with potable water. Replace
the fill cover and slide the water reservoir
to the operating position and replace the
drain tray. In order to connect the machine
up to the water mains proceed according
to the indications given in the Installation
Guide and in compliance with any local/
national safety standards of the location in
which the machine is being installed.
To guarantee a correct and safe functioning
of the machine and to maintain an adequate
performance level and a high quality of the
beverages being brewed it is important
that the incoming water be of a hardness
greater than 7°f (70ppm, 4°d) and less
than 10°f (100ppm, 6°d), pH should be
between 6.5 and 8.5 and the quantity of
chlorides be less than
3
0mg/l . Respecting
these values allows the machine to operate
at maximum efficiency. If these parameters
are not present, a specific filtration device
should be installed, while always adhering
to the local national standards in place
regarding potable water.
WARNING
The Coffee Boiler and Steam
Boiler contain water at
elevated temperature. Water
temperature over 125°F /
52°C can cause severe burns
instantly or death from scalding
(Coffee Boiler 207°F/97°C -
Steam Boiler 256°F / 124°C)
WARNING
Replace fuses with the same
size, type and rating. e.g. F1 =
2A, 250V
WARNING
The machine is intended to be
permanently connected to fixed
wiring, and it is mandatory that
a residual current device (RCD)
with a rated residual operating
current not exceeding 30mA is
installed.
Note:
• The drinking water mains valve and
the circuit breakers for the electrical
system need to be located in the most
convenient position for the operator to
access them easily and quickly.
• This machine complies with the
standard 61000-3-11, the impedance
at the supply interface must be Zmax=
0.
25
Ω.
WARNING
In order to prevent cracks
or leakage: do not store or
install the Coffee machine
in places where in boiler or
hydraulicsystem to freeze.