EN
12
Note:
• The drinking water mains valve and
the circuit breakers for the electrical
system need to be located in the most
convenient position for the operator to
access them easily and quickly.
• The machine should be placed on a flat
counter and must be placed in settings
with the following temperatures:
Minimum room temperature: 5°C/41°F;
Maximum
room
temperature:
32°C/89°F.
• If the machine has been temporarily
housed in settings with a room
temperature of less 0°C/32°F, the
machine must be placed in a warmer
environment in order to gradually
defrost the hydraulic system prior to
use.
• Water pressure supply must be between
4 and 8 bar.
• This machine complies with the
standard 61000-3-11, the impedance
at the supply interface must be Zmax=
0.11
Ω.
WARNING
In order to prevent cracks
or leakage: do not store or
install the Coffee machine
in places where in boiler or
hydraulicsystem to freeze.
1) Installation guide
For best results, STRADA needs a
minimum flow of water in input of 100 l/h
and a pressure of 2.5 bar.
Installations that do not meet these
requirements will cause a shorter life of
the pump and may cause a high noise
level during coffee brewing.
If the pressure and flow are not adequate,
air bubbles may develop within the gears.
This is called cavitation. Cavitation can
impair the performance of the espresso
machine.
If the incoming water of the espresso
machine falls outside the recommended
parameters, it is necessary to carry out one
of the following installations:
WATER TREATMENT
RECOMMENDED VALUES
www.lamarzocco.com/water_calculator
ROTARY PUMP
TEE FITTINGS
WATER CHECK POINT:
FLOW RATE < 100 l/h
PRESSURE
≤
9 BAR
WATER TREATMENT
RECOMMENDED VALUES
www.lamarzocco.com/water_calculator
TEE FITTINGS
WATER CHECK POINT:
FLOW RATE < 100 l/h
PRESSURE
>
9 BAR
ROTARY PUMP
PRESSURE REDUCER
PRESSURE
≤
9 BAR
WASTE/DRAIN
POWER SUPPLY
CORD
MAIN SWITCH
AND ELECTRICAL SUPPLY CONNECTION
WATER TREATMENT
RECOMMENDED VALUES
www.lamarzocco.com/water_calculator
MAIN WATER
SUPPLY VALVE
BRAIDED HOSE
TEE FITTINGS
COFFEE
BOILER
STEAM
BOILER
WATER CHECK POINT:
PORTATA ≥ 100 l/h
PRESSIONE ≥ 3 BAR
PRESSURE REDUCER
WATER CHECK POINT:
FLOW RATE ≥ 100 l/h
PRESSURE = 3 BAR
POWER SUPPLY
CORD
WASTE/DRAIN
MAIN SWITCH
AND ELECTRICAL SUPPLY CONNECTION
WASTE/DRAIN
MAIN SWITCH
AND ELECTRICAL SUPPLY CONNECTION
POWER SUPPLY
CORD
COFFEE
BOILER
STEAM
BOILER
COFFEE
BOILER
STEAM
BOILER
BRAIDED HOSE
BRAIDED HOSE
MAIN WATER
SUPPLY VALVE
MAIN WATER
SUPPLY VALVE
Fig. 3 - Installation guide - type 1
Pressure lower than 9 bar
Flow rate lower than 100 l/h
Installation with the rotary pump
immediately after the water treatment
system, upstream of the tee.