EN
11
6) Machine plate:
Machine CE plate
Machine ETL plate
Machine KC plate
Figure 2 - Expansion Valve Adjustment
Decrease
pressure
Increase
pressure
LINEAMINI
1620
60
14
115
12
7) Adjusting the expansion valve.
The expansion valve is a component
that limits the maximum pressure in
the Integrated brew group. Heating the
integrated brew group causes the water
within to expand. Since the integrated
brew group is completely saturated, the
expanding water causes an increase in
pressure within the boiler. Without a
safety device the increase in pressure
could cause a rupture in the boiler.
The pressure in the integrated brew group
should never exceed 12 bar. The valve is
hot, so, using adequate protection, rotate
the expansion valve clockwise to increase
pressure. To decrease pressure, rotate the
expansion valve counter clockwise (see the
following diagram).