EN
45
Display
Operating Procedure
Description
Doses Setting
select within 30s
• This parameter allows the operator
to program the water volume (shot
volume) for the individual buttons on
the keypad.
• The saved program is a number. This
number relates to the number of
pulses the flowmeter delivers to the
CPU. Once the programmed number of
pulses is received by the CPU, the flow
of water is stopped.
• This parameter is not available on MP
Paddle model as volume is manually
controlled by use of paddle.
“Machine ON” Programming
Water Volume Programming
1
2
3
Enter into “Machine On” programming mode.
Press one of the following buttons:
Water will begin to flow. When the desired amount of water has been dispensed, press the same button again to
Stop the flow of water. The button is now programmed. Repeat this process for subsequent buttons.
200.5
o
F 06:30
La Marzocco T:00
Doses Setting
Select within30s
Summary of Contents for GS/3
Page 30: ......