INSTALLATION, OPERATING AND TROUBLESHOOTING INSTRUCTIONS FOR MODEL A75D / A75DE –

THREE PHASE

 

Page 11 of 20 

 

POWER CABLING FORMULAS 

 

SIZE 

AWG.

 

AREA 

CIR. 

MILS

 

SIZE 

AWG. 

MCM*

 

AREA 

CIR. 

MILS

 

SIZE 

 

MCM*

 

AREA 

CIR. 

MILS

 

18 

1620 

83690 

600 

600000 

16 

2580 

1/0 

105600 

700 

700000 

14 

4110 

2/0 

133100 

750 

750000 

12 

6530 

3/0 

167800 

800 

800000 

10 

10380 

4/0 

211600 

900 

900000 

16510 

250 

250000 

1000 

1000000 

26240 

300 

300000 

1250 

1250000 

41740 

350 

350000 

1500 

1500000 

52620 

400 

400000 

1750 

1750000 

66360 

500 

500000 

2000 

2000000 

 

*DENOTES ALL SIZES LARGER THAN =0000 ARE EXPRESSED IN MCM.

 

 
 
 

TABLE OF CONVENTIONS 

CMA  =  Cross section of wire in circular MIL area 

A  =  Ultimate drain in amperes 

LF  =  Conductor loop feet 

MAX AMP  =  Maximum allowable amperes for given voltage drop 

AVD  =  Allowable voltage drop 

K  =  11.1  Constant  factor  for  commercial  (TW  type)  copper  wire 

(KS5482-01) 

  =  17.4 for aluminum (KS20189) 

 

Calculating Wire Size Requirements 

 

CMA 

 

A X LF X K 

   

AVD 

 

Calculating Current carrying capacity of wire 

 

Max Amp 

 

CMA X AVD 

   

LF X  K 

 
 

Source:  Handbook 100-National Bureau of Standards 
NOTE:  All Wire #6 and larger is stranded. 

Summary of Contents for A75D

Page 1: ...Digital METERS THREE PHASE ECN DATE CPN124997 20535 8 14 20098 8 13 20084 8 13 19784 12 12 106 BRADROCK DRIVE DES PLAINES IL 60018 1967 847 299 1188 FAX 847 299 3061 ISSUE DATE ECN 19609 7 12 INSTRUCT...

Page 2: ...UTMOST IMPORTANCE THAT EACH TIME BEFORE USING THIS UNIT YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY To reduce risk of battery explosion follow these instructions and those published by t...

Page 3: ...Gases from the battery will corrode and damage equipment A sealed maintenance free or valve regulated lead acid VRLA may be placed below this equipment Never allow the battery electrolyte to drip on t...

Page 4: ...provide a copy of the claim to La Marche Mfg may void warranty service for any physical damages reported for repair HANDLING WARNING Equipment can be very heavy and top heavy Use adequate manpower or...

Page 5: ...f the battery cables charger output and relay rack terminals Connect the proper battery cable to the ground bar or battery charger output terminal Energize the power supply by turning on the units AC...

Page 6: ...75D A75DE series battery chargers provide separate voltage adjustments for floating or equalizing lead or nickel cadmium cells The float or equalize mode of operation is selected by pressing the equal...

Page 7: ...E PHASE VOLTAGE MODEL NUMBER D B C A75D A75DE 208 240 480 50 24V 30 26 13 75 24V 44 38 19 100 24V 59 51 26 125 24V 74 64 32 150 24V 89 77 38 200 24V 118 102 51 50 48V 15 13 6 75 48V 22 19 10 100 48V 3...

Page 8: ...E terminals of all chargers can be connected together to ensure all chargers automatically switch into and out of equalize mode together PROTECTION Current Walk In The output current gradually increas...

Page 9: ...terminals together If the charger is equipped with a Remote Equalize Terminal connect the RE terminals together CURRENT WALK IN Output current will gradually increase after the battery charger is tur...

Page 10: ...INFORMATION MINIMUM WIRE SIZES See Wire Size Chart lists the ac input and dc output minimum wire size requirements At distances exceeding 10 feet the dc wire size should be chosen to keep the voltage...

Page 11: ...500000 3 52620 400 400000 1750 1750000 2 66360 500 500000 2000 2000000 DENOTES ALL SIZES LARGER THAN 0000 ARE EXPRESSED IN MCM TABLE OF CONVENTIONS CMA Cross section of wire in circular MIL area A Ult...

Page 12: ...le lists the AC input and the DC output minimum wire size requirements At distances exceeding 10 feet the DC wire size should be chosen to keep the voltage difference between the units DC output termi...

Page 13: ...done in the following order single power supply 1 Connect AC input line to the terminal block provided Be sure the AC circuit breaker is off 2 Observe the polarity of the battery cables and the rectif...

Page 14: ...changing the rectifier current limit between 50 110 of rated output Turning the adjustment which is located on the unit front panel clockwise lowers the current limit turning counterclockwise raises...

Page 15: ...lashing LED Solid LED High DC voltage 2 45 Vpc Lead Acid High DC voltage shutdown HVSD 2 5 Vpc Lead Acid Low DC current 5 A Timer mode Mode 0 Equalize Time 8 Hours OPT 46R RELAY PACKAGE 2 SETS OF FORM...

Page 16: ...indicate The timer will automatically return the charger to the float mode when the equalize cycle is complete MODE 1 DISPLAY indicates P01 This mode of operation automatically starts an equalize cycl...

Page 17: ...can be caused by defective batteries and customer loads make sure batteries and loads are free from defects NOTE If the problem is found to be located in the printed circuit boards the board should be...

Page 18: ...output Meter should not indicate If the meter reads full scale deflection this indicates an ac dc short During shipping an AC wire may rub against the DC lugs terminals etc and cause a short These pro...

Page 19: ...nal components 4 Check front panel meters and alarms for accuracy 4th Year REPEAT ABOVE WITH THE ADDITION OF 1 Check relay contacts for pitting or corrosion 2 Check capacitors for leakage 7th Year REP...

Page 20: ...r installation installation adjustments and service arrangements Should minor adjustments be required the local La Marche sales representative should be contacted to provide this service only All sale...

Reviews: