Page 1: ...Page 1 of 12 MODEL A45E BATTERY CHARGER ECN DATE CPN35921 14575 2 01 15349 10 8 02 14268 10 00 106 BRADROCK DRIVE DES PLAINES IL 60018 1967 847 299 1188 FAX 847 299 3061 ISSUE DATE 10378 9 96 INSTRUCT...

Page 2: ...UCTIONS EXACTLY To reduce risk of battery explosion follow these instructions and those published by the battery manufacturer and manufacturer of any equipment you intend to use in the vicinity of the...

Page 3: ...amage equipment A sealed maintenance free or valve regulated lead acid VRLA may be placed below this equipment Never allow the battery electrolyte to drip on this unit when reading the specific gravit...

Page 4: ...to La Marche Mfg may void warranty service for any physical damages reported for repair HANDLING WARNING Equipment can be very heavy and top heavy Use adequate manpower or equipment for handling Until...

Page 5: ...The Model A45E features Microprocessor based control Automatic start stop circuitry Automatic Sensing of Fully Charged Battery Automatic 12 hour override timer 3 Hour timing after 80 normal mode 6 Hou...

Page 6: ...m the battery must be connected to a terminal marked NEGATIVE or NEG and the positive wire from the battery must be connected to the terminal marked POSITIVE or POS on the battery charger OPERATION ST...

Page 7: ...n the a c has returned to normal the charge cycle resumes where it left off CAUTION Turn the on off switch to the off position when disconnecting the battery during the charge cycle to prevent arcing...

Page 8: ...MODEL A45E INSTRUCTION MANUAL Page 8 of 12 FIGURE 1...

Page 9: ...charging problems that arise from a varying line when charging continually day and night or for two or three shift operations The unit is self protecting when subjected to abnormal overloading condit...

Page 10: ...ents must be made the taper and shutdown point may be adjusted This adjustment may be made by moving the red slider band on the voltage reference variable resistor RV1 Moving this slider band toward t...

Page 11: ...1 Check battery for defective or shorted cells 2 S2A 122A p c board may be defective CODE 0005 Not used Problem Failure light CODE 0006 1 Check for defective or shorted cells in battery 2 Check finis...

Page 12: ...f the purchaser elects not to return the equipment to the factory and wishes a factory service representative to make adjustments and or repairs at the equipment location La Marche s field service lab...