Pressing Finish will complete the IP setting change process.   The DeviceInstaller Application can now be 

closed. 

 
 
 
 
 
 
 
 

LaMarche Modbus Implementation  

 

 

  

MODBUS - RTU,           BAUD RATE - 115200,               PARITY - NONE,            

 SLAVE ID - 0,             STOP BIT - 1 BIT                               

Sr No.

 

PARAMETER DETAIL

 

  

 MAIN CARD  

Modbus 

Register 
Address 

Variable Type 

UNIT 

Range 

 

 

 

 

M_HT_TEST_LOAD_KVA

 

  

  

  

  

M_HT_TEST_START_VOL 

30002 

unsigned int 

kva 

  

M_HT_TEST_END_VOL 

30003 

unsigned int 

volt/cell 

  

M_BATT_HEALTH_STATUS

 

30004 

unsigned int 

volt/cell 

  

M_CT_TEST_LOAD_KVA

 

30005 

unsigned int 

  

M_CT_TEST_START_VOL 

30006 

unsigned int 

kva 

  

M_CT_TEST_END_VOL 

30007 

unsigned int 

volt/cell 

  

M_CT_TEST_PERCENTAGE 

30008 

unsigned int 

volt/cell 

  

Summary of Contents for 21Q

Page 1: ...rial port Option 21Q TCP IP and RS 232 serial provided on 383S Communication Board Option 21S RS 232 serial provided via RS 485 to RS 232 converter ECN DATE CPN 147722 106 BRADROCK DRIVE DES PLAINES I...

Page 2: ...tions card may be configured for RS232 TCP communications SW2 configures the board for either Serial or TCP IP communications SW4 leave in RS 232 communication For RS 485 communication connect directl...

Page 3: ...is set at the factory as follows IP Address 192 168 0 6 Netmask 255 255 255 0 Gateway 192 168 0 1 TCP Port Number 502 To change the TCPIP settings it is necessary to load and install the DeviceInstal...

Page 4: ...ettings press the Assign IP button on the Toolbar This will bring up the following screen The Device Identification is located on the device itself as described in the dialog text above An example of...

Page 5: ...D press Next This dialog presents a choice between assigning an IP dynamically which would allow the device to operate on a network with a DHCP server however it is recommended that a specific IP addr...

Page 6: ...r your desired IP settings and press Next Pressing Assign will start the process of programming the device to the new IP Settings A progress bar and Status will appear indicating a successful operatio...

Page 7: ...ARAMETER DETAIL MAIN CARD Modbus Register Address Variable Type UNIT Range 1 M_HT_TEST_LOAD_KVA 2 M_HT_TEST_START_VOL 30002 unsigned int kva 3 M_HT_TEST_END_VOL 30003 unsigned int volt cell 4 M_BATT_H...

Page 8: ..._TOTAL_POWER 30027 unsigned int Kwh 28 M_GRID_AVG_POWER_FACTOR 30028 unsigned int Kw 29 M_BATTERY_VOLTAGE 30029 unsigned int NA 30 M_BATTERY_CHG_CURRENT M_BATTERY_DISCHG_CURRENT 30030 unsigned int V 3...

Page 9: ...ACTOR 30062 unsigned int Kw 65 S_BYPASS_VOLTAGE 30063 unsigned int NA 66 S_BYPASS_LOAD 30064 unsigned int V 67 S_BYPASS_FREQUENCY 30065 unsigned int A 68 S_FINAL_OUTPUT_VOLTAGE 30066 unsigned int Hz 6...

Page 10: ...argerFlags BATTERY_HEALTH_TEST_RESULT Bit 7 ChargerFlags BATTERY_HEALTH_TEST Bit 6 ChargerFlags FLOAT_EQ_MODE Bit 5 ChargerFlags CHARGING_DONE_STATUS Bit 4 ChargerFlags BATTERY_CAPACITY_END Bit 3 Char...

Page 11: ...ER_INV_FAN_FAIL Bit 4 Flags2 FUSE_FAIL Bit 3 Flags2 PhaseInSync Bit 2 Bit 1 M_SYSTEM_STATUS 2 Flags2 SYSTEM_3PH_1PH_OUT 0 3Phase 1 1Phase Flags2 VOLTAGE_220V_OR_120V 0 220 1 120 Bit 8 Flags2 FREQUENCY...

Page 12: ...sCurrentRefOK Bit 7 Flags2 BypassVoltageRefOK Bit 6 Flags2 InvFBVoltageRefOK Bit 5 TransferTestResult 2 Bit 4 Bit 3 M_BATT_HEALTH_STATUS Value 0 to 100 Load Insufficient 155 Battery Low During Test 15...

Reviews: