background image

 

             

 

 

Kantooradres: 

Postadres: 

 

 

Vlijtstraat 40  

Postbus 127 

 

 

NL-7005 BN Doetinchem

 

NL-7000 AC 

 

H.R. te Arnhem nr: 09087869

 

Tel:  (+31)  314 376 876 

 

E-mail: [email protected] 

Internet: http://www.lagard.nl 

BTW nr: NL 8038.72.987.B01 

Fax: (+31)  314 376 878

 

 

LG 39E Combogard EN 

Revise: 1

 

 

Datum: 16-02-05

 

 

LA GARD Locks BV

 

OPERATING INSTRUCTIONS LG 39E Multi User Combogard

 /

Swingbolt 

Keypad 3035, 3710, 3750 or 3750K with reading contact 

    

Lock 39E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Generally 

Each pressing of a key is confirmed by a signal (an acoustic signal and a LED flash). A valid code is 

followed by a double signal, an invalid code by a triple signal. After an interval of more than 10-seconds, 

the already entered part of the code is deleted and the entire sequence has to be re-entered. 

 

Code entering:

 

Enter the seven-digit numeric code–or a word with 7 characters 

a) Operation with parallel code:  

a double signal is followed. 

 (manager mode) 

 

 

Manager code: 1234567

 

 

b) Operation with dual codes: 

Six-digit numeric codes or words with six characters. 

 (must be programmed) 

For opening two valid codes must be entered.  

Manager code: 123456 and User ID# 654321

 

 

Opening:

 

Combogard:

 Enter the code and (after double signal) turn the 

entry clockwise within 3 seconds unto the hold. The lock is open 

and the entry is rotated.  

Swingbolt:

 Enter the code and (after double signal) turn the 

handle within 3 seconds into the OPEN position. 

 

If  the  lock  is  not  opened  within  3  seconds,  it  is  automatically 

locked again. 

 

Locking:

 

 

 

 

Combogard:

 Turn the entry counter-clockwise unto the hold. 

The lock is automatically closed and the entry stands straight. 

(Check this by trying to turn the entry back again) 

Swingbolt:

 Turn the handle into the CLOSE position.  

The lock is automatically locked; check this by trying to turn the 

handle into “OPEN” position. 

 

 

I M P O R T A N T

 

 

Check the lock to be locked. 

 

Wrong try penalty:

 

 

 

After four invalid codes, the entry is blocked for about 5 

minutes. During this period, the lock signals at 10-second 

intervals. After this time penalty, the entry of every second 

invalid code initiates a new 5 minutes delay period.  

 

The key pressing is refused with a triple signal. 

 

Change of code:

 

The user can change its code anytime. 

(always with open door) 

 

Enter the code and keep pressed the last number until second 

double signal (LED is on), press the “0” and enter the new code 

(double signal), enter the new code once more for confirmation 

(double signal). 

 

   

 

 

 

The new code is now valid. If mistakes are made while 

changing the code or if an interval occurs of more than 10 

seconds, the old code remains valid and the entire sequence 

has to be re-entered. 

Test the new code several times by open door! 

Contact of 

the audit trail

 

LED

 

3035 

3710 

3750 

3750K 

Get other manuals https://www.bkmanuals.com