background image

WS6205 Instruction Manual

 

 

 

 

Features

 DCF Radio control time function 

 Perpetual Calendar Up to Year 2099 

 Day of week in 15 languages user selectable: English, German, French, Spanish, Italian, Dutch, Danish, Portuguese, 

Norwegian, Swedish, Polish, Finnish, Czech, Hungarian, and Russian 

 Time in optional 12/24 hour format. 

 Daily Alarm Function 

 Automatic snooze function 

 Barometric pressure: 

          — Barometric pressure measurement ranges: 600 hPa/mb

1100 hPa/mb & 17.72 inHg

32.50 inHg   

          — Pressure alternatively in hPa/mb or inHg   

 Humidity: Indoor & OUT measurable range: 20%RH ~ 95%RH 

 Temperature: 

  — Indoor temperature measurement ranges: -9.9°C (13.9°F) ~ 50°C (122°F) 

—OUT temperature measurement ranges: -40°C (-44°F) ~ 70°C (158°F) 

— Temperature alternatively in °C or °F. 

—OUT thermometer and frost alert

 

 Minimum/maximum display for air humidity and temperature 

 Wireless OUT Sensor: 

— Wall Mount or Table Stand   

— One Wireless Thermo Sensor Included   

— 433.92MHz RF transmitting frequency   

— 60 meter transmission range in an open area 

 The weather forecasting function 

 Power Supply:   

Weather Station: 

Battery: 2 x LR6 AA 

     

Wireless Remote Sensor:   

Battery:2 x LR3 AAA

 

F.Y.I.:   

The wireless remote sensor can work at -30°C to +70°C.

 

Please choose the right battery according to the limit 

temperature of the wireless sensor: 

  Alkaline zinc manganese battery can work at -20°C to +60°C 

Polymer lithium ion rechargeable battery can work at -40°C to +70°C. 

 

   

 

 

 

Summary of Contents for WS6205

Page 1: ...easurement ranges 9 9 C 13 9 F 50 C 122 F OUT temperature measurement ranges 40 C 44 F 70 C 158 F Temperature alternatively in C or F OUT thermometer and frost alert Minimum maximum display for air humidity and temperature Wireless OUT Sensor Wall Mount or Table Stand One Wireless Thermo Sensor Included 433 92MHz RF transmitting frequency 60 meter transmission range in an open area The weather for...

Page 2: ... time Day A5 Barometric pressure A6 Histogram shows the trend of 24 hours of atmospheric pressure A7 Indoor Humidity A8 Indoor comfort A9 Indoor Temperature A10 Weather Forecasting A11 Outdoor comfort Part B Back button and power B1 touch field B2 button B3 button B4 button B5 button B6 button B7 button B8 MEM button B9 Power adapter B10 Battery compartment ...

Page 3: ...05 Instruction Manual Part C Wireless Remote Sensor C1 LCD display Temperature C2 LCD display Humidity C3 Transmit signal LED C4 C F button C5 TX button C6 CHANNEL 1 or 2 or 3 switch C7 Battery compartment ...

Page 4: ...t 1 00 2 00 3 00 am the clock automatically carries out the synchronization procedure with the DCF signal to correct any deviations to the exact time If this synchronization attempt is unsuccessful the radio mast icon disappears from the display the system will automatically attempt another synchronization at the next full one hour This procedure is repeated automatically up to total 5 times To st...

Page 5: ...setting the Time zones start to flash Now use and buttons set a correct time zone 12 to 12 Press to confirm your setting the 12 24 hour mode display starts to flash Now use and buttons to set the correct 12 24 hour mode Press to confirm your setting the Hour display starts to flash Now use and buttons to set the correct hour Press to confirm your setting the Minute displays starts to flash Now use...

Page 6: ...ATERDAG ZONDAG DUT MAA DIN WOE DON VRI ZAT ZON DANISH MANDAG TIRSDAG ONSDAG TORSDAG FREDAG LØRDAG SØNDAG DAN MAN TIR ONS TOR FRE LOR SON NORWEGIAN MANDAG TIRSDAG ONSDAG TORSDAG FREDAG LØRDAG SØNDAG NOR MAN TIR ONS TOR FRE LOR SON SWEDISH MÅNDAG TISDAG ONSDAG TORSDAG FREDAG LÖRDAG SÖNDAG SWE MAN TIS ONS TOR FRE LOR SON POLISH PONIEDZIAŁEK WTOREK ŚRODA CZWARTEK PIĄTEK SOBOTA NIEDZIELA POL PON WTO SR...

Page 7: ...et the alarm repeat in M F from Monday to Friday or S S Saturday and Sunday or M S from Monday to Sunday Press button to confirm your setting switch to the alarm 2 hour setting Use the and buttons to set the required hour Press button to confirm your setting switch to the alarm 2 minute setting Use the and buttons to set the required minute Press button to confirm your setting switch to the alarm ...

Page 8: ...ry to reactivate the alarm It switches itself automatically to the alarm time which has already been set Snooze function Touch the field or press the button the alarm signal sounds to get to SNOOZE mode The alarm signal sounds again after approx 5 minutes C F temperature display The temperature is displayed either in C F Briefly pressing the button allows you to switch between the individual modes...

Page 9: ...play each channel every 5 seconds automatically If the weather station failed to receive transmission from remote sensor display on the LCD press and hold button for 3 seconds to receive transmission manually the remote temperature will show an animation of the RF antenna symbol the Base Station will re receive the wireless signal of the remote sensor F Y I when the wireless sensor set up differen...

Page 10: ...rocedure F Y I Before entering the setup you must select the remote channel different channels can set different temperature alarm range Temperature and frost alert Press button to activate or deactivate the remote temperature alert When the remote temperature alarm is activated the temperature alarm icon is displayed in the remote sensor bar When the remote channel temperature value exceeds the s...

Page 11: ...cast from your local weather forecasting service into account as well as the forecast from your weather station If there are discrepancies between the information from your device and from the local weather forecasting service please take the advice of the latter as authoritative The weather station displays the following weather symbols sunny slightly cloudy cloudy rainy Snowy The weather station...

Page 12: ...ange after entering the night Press button to confirm your setting switch to the hour of enter night mode setting Now use and buttons set the required hour Press button to confirm your setting switch to the minute t of enter night mode setting Now use and buttons set the required minute Press button to confirm your setting switch to the hour of exit night mode setting Now use and buttons set the r...

Page 13: ...onnect the power supply into an easily accessible DC outlet Ensure that the power cord can not be crushed or pinched particularly at plugs convenience receptacles and the point where they are connected to the apparatus The supplied power supply is intended for indoor use only Do not place naked flame sources such as a lit candle on or near the power supply Unplug this power during lightning storms...

Page 14: ...correct readings and any consequences that occur should an inaccurate reading take place This product is designed for use in the home only as indication of the temperature The plug on the power adapter if included is intended to serve as the disconnect device the socket outlet shall be installed near the equipment and shall be easily accessible This product is not to be used for medical purposes o...

Reviews: