1. 

The hour digit will start flashing. 

2. 

Use the OUT/+ key to set the hour. 

3. 

Press again the SET key to set the minutes. The minute digits start 
flashing. 

4. 

Use the OUT/+ key to set the minutes. 

5. 

Confirm with the SET key and enter the Calendar setting.

  

 

Note: If the WWVB reception function is set to "ON", the unit will still try to 
receive the WWVB time signal between midnight and 6:00 am every day, 
even if the time was set manually. When it does receive the signal, it will 
change the manually set time into the received time. During reception 
attempts, the WWVB tower icon will flash. If reception has been 
unsuccessful, then the WWVB tower icon will not appear but reception 
will still be attempted the following hour. 

 

 

CALENDAR SETTING:

 

 
 
 
 

Year  

 

26 

 

 

 
 

 

 

 

Note: 

When set to 24-hour time, the calendar setting mode will display 

the date to the left of the month.   

 

The date default of the Weather station is 1. 1. 2006. Once the radio-
controlled time signals are received, the date is automatically updated. If 
the signals are not received, the date can also be set manually.  
1. 

The year starts flashing. 

2. 

Use the OUT/+ key to set the year (between year 2003-2029).  

3. 

Press the SET key again to confirm and to enter the month setting. 
The month starts flashing. 

4. 

Use the OUT/+ key to set the month.  

5. 

Press the SET key again to confirm and to enter the date setting 
mode. The date starts flashing. 

6. 

Use the OUT/+ key to set the date. 

7. 

Confirm all calendar settings with the SET key and enter the 
Temperature unit setting. 

Month and date 
(12hr time format) 
Date and month 
(24hr time format) 

 

27 

 

Note

: The Day of the Week will set automatically when the year, month 

and date are set. 

 

°C/°F TEMPERATURE SETTING: 

 

 

 

 

 

The temperature display can be selected to show temperature data in °C 
or °F (Default °F). 
1. 

Use the OUT/+ key to toggle between “°C” and “°F”. 

2. 

Confirm with the SET key and enter the 

Air pressure unit setting. 

 

AIR PRESSURE UNIT SETTING (hPa / inHg): 

The pressure display can be selected to show relative air pressure in hPa 
or inHg (default is “inHg”). 

 

 
 

 
 
 

Flashing

Flashing

 

28 

 

1. 

Use the OUT/+ key to toggle between “hPa” or “inHg” unit 

2. 

Confirm with the SET key and enter the 

Relative air pressure 

value setting

Note:

  

Units of weather icon sensitivity and air pressure history are not affected. 
They are always expressed in hPa. 

 

RELATIVE AIR PRESSURE VALUE SETTING 

The default relative pressure value is 29.92 inHg (1013 hPa). This can be 
manually set to another value within the range of 28.35 – 30.72 inHg (960 
– 1040 hPa) for a better reference. 

 
 
 
 
 

 
 

1. 

The current relative pressure value will start flashing 

2. 

Use the OUT/+ key to increment and IN key to decrement the 
value. Holding the key allows the value to advance faster. 

Flashing 

Summary of Contents for WS-9049

Page 1: ...ar graph 37 Outdoor temperature and humidity 38 Toggling and resetting the outdoor data 39 915MHz reception 41 Mounting 42 Care and Maintenance 45 Specifications 46 Warranty Information 48 3 INVENTORY...

Page 2: ...me reads 12 00 If this information is not displayed on the LCD after 60 seconds remove the batteries and wait for at least 60 seconds before reinserting them Once the indoor data is displayed you may...

Page 3: ...n 330 feet to ensure sufficient 915 MHz transmission See notes on Positioning and 915 MHz Reception IMPORTANT Transmission problems will arise if the setup for additional sensors is not followed as de...

Page 4: ...y night when reception is best The WWVB radio station receives the time data from the NIST Atomic clock in Boulder Colorado A team of atomic physicists is continually measuring every second of every d...

Page 5: ...tdoor data 19 Moon phase icon Weather tendency indicator Time Calendar or alarm time Indoor relative humidity in RH Time reception icon for WWVB time Indoor temperature in F C Weather forecast icon Ou...

Page 6: ...l display 2 Use the OUT key to turn the daylight saving time function ON or OFF Flashing 23 3 Confirm with the SET key and enter the Time reception ON OFF setting TIME RECEPTION ON OFF SETTING In area...

Page 7: ...4 Use the OUT key to set the month 5 Press the SET key again to confirm and to enter the date setting mode The date starts flashing 6 Use the OUT key to set the date 7 Confirm all calendar settings wi...

Page 8: ...igits flash 2 Use the IN key to set the alarm hour 3 Use the OUT key to set the alarm minute 4 Confirm with SNOOZE CH key and exit the Alarm setting The icon will be displayed along with the set alarm...

Page 9: ...he icons do not change then it means either the air pressure has not changed or the change has been too slow for the Weather station to register If the icon displayed is a sun or raining cloud there w...

Page 10: ...e past pressure was compared to the current pressure If the bars are rising it means that the weather is getting better due to the increase of air pressure If the bars go down it means the air pressur...

Page 11: ...cal products such as headphones or speakers operating on the 915MHz signal frequency may prevent correct signal transmission or reception Neighbors using electrical devices operating on the 915MHz sig...

Page 12: ...h the unit may invalidate their guarantee Do not expose the units to extreme and sudden temperature changes this may lead to rapid changes in forecasts and readings and thereby reduce their accuracy 4...

Page 13: ...damage resulting from the performance of repairs or alterations by someone other than an authorized La Crosse Technology Ltd authorized service center 6 units used for other than home use 7 applicati...

Reviews: