background image

 

18

SPECIFICATIONS 
 
Weather data measuring range: 

Indoor: 

14.2

°

F to 139.8

°

F with 0.1

°

resolution (0

°

C to 59.9

°

C with 

0.1

°

C resolution) “OFL” 

displayed if outside this range 

Outdoor and dew point: 

-21.8

°

F to 157.8

°

F with 0.1

°

resolution (-29.9

°

C to 69.9

°

with 0.1

°

C resolution) “OFL” 

displayed if outside this range 

Wind chill: 

-21.8

°

F to 157.8

°

F with 0.1

°

resolution (-29.9

°

C to 69.9

°

with 0.1

°

C resolution) “OFL” 

displayed if outside range 

Indoor relative humidity 
measuring range: 

1% to 99% with 1% resolution 
(“- -” displayed if outside this 
range 

Outdoor relative humidity 
measuring range: 

1% to 99% with 1% resolution 
(“- - “ displayed if outside this 
range 

Wind speed measuring range: 

0 to 111.8 mph (0 to 50 m/s) 

Weather data checking interval: 

Indoor temperature checking 
interval: 

Every 15 seconds 

Indoor humidity checking 
interval: 

Every 20 seconds 

Outdoor temperature checking 
interval (remote 
temperature/humidity sensor): 

Every 128 seconds 

Outdoor humidity checking 
interval: 

Every 128 seconds 

Wind speed checking interval: 

Average of 128 seconds with 
highest gust 

Outdoor temperature, humidity 
and wind speed reception 
(indoor weather station): 

Every 128 seconds 

Transmission range: 

300 feet (in open space) 

Power Supply: 

Indoor weather station: 

3 x AA, IEC LR6, 1.5V 

Remote temperature/humidity 
sensor: 

2 x AA, IEC LR3, 1.5V 

Remote wind speed sensor: 

Supplied by remote 
temperature/humidity sensor 

Battery life cycle: 

Approximately 12 months 

Recommended battery type: 

Alkaline 

Dimensions (H x W x D): 

Indoor weather station: 

9” x 4.62” x 1.25” 
(227 x 117.4 x 31.2 mm) 

Remote temperature/humidity 
sensor: 

5.4” x 2.25” x 2.25” 
(137 x 56.2 x 56.2 mm) 

Remote wind speed sensor: 

7.5” x 2.2” x 2.2” 
(191.2 x 55.8 x 56 mm) 

 
 
 
 
 
 

Summary of Contents for WS-9035TWC

Page 1: ...WS 9035TWC Wireless 433 MHz Radio controlled Weather Station Instruction Manual...

Page 2: ...etting the Time 8 Setting the Year Day and Month 9 Setting the Snooze 9 Setting the Temperature Format 9 Setting the Forecast Sensitivity 10 Features Weather Forecast Icons and Tendency Arrows 11 Indo...

Page 3: ...continuously throughout the United States at 60 kHz The signal can be received up to 2 000 miles away through the internal antenna in the Weather Station However due to the nature of the Earth s Iono...

Page 4: ...ugh will reduce distance An outdoor wall or window can have up to 30 feet of resistance and an interior wall can have up to 20 feet of resistance Your distance plus resistance should not exceed 300 ft...

Page 5: ...correct time default time zone is Eastern You will need to adjust the time zone to match your local time PROGRAM MODE Programming Note If 30 seconds are allowed to pass or the WIND SNZ button is press...

Page 6: ...Atlantic 4 EST Eastern 5 CST Central 6 MST Mountain 7 PST Pacific 8 ALA Alaska 9 HAW Hawaii 10 6 Press and release the SET button to confirm and advance to the Daylight Saving Time setting V DAYLIGHT...

Page 7: ...tion is at night between midnight and 6 00 am when there is less atmospheric interference To keep your time as accurate as possible the indoor weather station conducts a WWVB search every night betwee...

Page 8: ...t the duration of the snooze Note The snooze can be set for 0 to 30 minutes in 5 minute increments If 0 minutes is selected pressing the WIND SNZ button will deactivate the alarm and it will not come...

Page 9: ...a necessity to disregard all weather forecasting for 12 24 hours after the unit has been set up reset or moved from one altitude to another i e from one floor of a building to another floor In areas w...

Page 10: ...ator is located at the bottom left of the INDOOR LCD The indicator will display a happy face icon when the temperature is between 68 F and 79 F 20 C and 25 9 C and the humidity is between 45 and 64 A...

Page 11: ...either MAX or MIN 2 Press and hold the SET button for 5 seconds 3 The record is now reset and will show the current time in the TIME LCD and current outdoor temperature and humidity in the OUTDOOR LC...

Page 12: ...s and hold the WIND SNZ button for 3 seconds 2 The WIND SPEED LCD will now show the maximum wind 3 Press and release the WIND SNZ button again 4 The WIND SPEED LCD will now show the maximum wind gust...

Page 13: ...3 18 mph 20 28 kph 11 16 knots Moderate Breeze Small branches move raises dust leaves and paper Small waves develop becoming longer whitecaps 5 19 24 mph 29 38 kph 17 21 knots Fresh Breeze Small trees...

Page 14: ...ss and hold the ALM button for 5 seconds 2 The alarm time will begin to flash in the DATE LCD 3 Press and release the IN HR button to adjust the hour Note When in the 12 hour mode and setting an alarm...

Page 15: ...RE HUMIDITY SENSOR The remote temperature humidity sensor can be mounted in several ways With the use of screws Using adhesive tape Using nylon straps A MOUNTING WITH SCREWS 1 Remove the mounting brac...

Page 16: ...y 3 16 of an inch 5mm extended from the wall 2 Place the indoor weather station onto the screw using the hanging hole on the backside 3 Gently pull the indoor weather station down to lock the screw in...

Page 17: ...absorb and store heat from external sources i e handling of the case or radiant heat Also the much greater range of the remote temperature humidity sensor requires a different calibration curve than...

Page 18: ...ature checking interval Every 15 seconds Indoor humidity checking interval Every 20 seconds Outdoor temperature checking interval remote temperature humidity sensor Every 128 seconds Outdoor humidity...

Page 19: ...erefore the above exclusion of limitation may not apply to you For warranty work technical support or information contact La Crosse Technology 2809 Losey Blvd S La Crosse WI 54601 Phone 608 782 1610 F...

Reviews: