background image

 

 

TOGGLING AND RESETTING THE OUTDOOR RECORDINGS: 

1. 

To toggle between the outdoor current, MIN/MAX temperature and 
humidity data and the times  (for temperature data only) they were 
recorded press the MIN/OUT key: 
Once to show the MAX outdoor temperature and humidity data with the 
recorded time and date.  
Twice to show the MIN outdoor temperature and humidity data with the 
recorded time and date.  
Three times to return to the current displayed values.  

2. 

To toggle between sensors, press the CH/+ key: 
Once to show sensor 2 
Twice to show sensor 3 
Three times to return to sensor 1 

Note:  The sensor number will only be displayed if there is more than one 

sensor being used

3. 

To reset the MIN/MAX outdoor temperature, and the time at which they 
were recorded, press and hold the MIN/OUT key for about 4 seconds. 
This will reset all MIN/MAX data recorded to the displayed values for 
that particular sensor.  

 

TO EXIT THE MANUAL SETTING MODE 

To exit the manual setting mode anytime during the manual setting modes, 
press the SNOOZE key anytime or wait for automatic timeout. The mode will 
return to normal time display. 

 

BACK-LIGHT 

The back-light is automatically switched ON when any keys are pressed. The 
back-light will be switched on for approximately 10 seconds before 
automatically switching OFF. However, if the SNOOZE key is pressed and 
held down, then back-light will remain ON constantly until the key is released.

 

 

ABOUT THE OUTDOOR THERMO-HYGRO SENSOR 

The range of the Thermo-hygro Sensor may be affected by the temperature. 
At cold temperatures the transmitting distance may be decreased. Please bear 
this in mind when positioning the sensor. Also the batteries may be reduced in 
power. 

 

CHECKING FOR 433MHz RECEPTION 

If the outdoor temperature and humidity data is not being received within 
three minutes after setting up (the display shows “- -. - °F” and “- -%” on the 
outdoor section of the Weather Projection Station after 3 attempts during 
normal operation), please check the following points: 

Summary of Contents for WS-9025U

Page 1: ...y for technical mistakes or printing errors or their consequences All trademarks and patents are acknowledged FCC ID OMO 01RX receiver OMO 01TX sensor THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULE...

Page 2: ...d time date calendar moon phase indoor and outdoor temperature indoor and outdoor relative humidity this unit will never keep you guessing on current and future weather conditions Operation of this pr...

Page 3: ...MAX records and time of reception Indoor and outdoor temperature display in C F Humidity data with MIN MAX records Indoor and outdoor humidity display as RH Can receive up to 3 sensors Time projection...

Page 4: ...move the battery cover 2 Insert the batteries observing the correct polarity see marking 3 Replace the battery cover on the unit Note In the event of changing batteries in any of the units all units n...

Page 5: ...o sensors If you have purchased additional sensors repeat from step 3 for all extra sensors However ensure that you leave 10 seconds in between the reception of the last sensor and the set up of the f...

Page 6: ...the moon icon the weather icons sun and clouds will be displayed If the indoor temperature and indoor humidity are not displayed after 15 seconds remove the batteries and wait for at least 3 minutes b...

Page 7: ...ception attempt will occur on the following day Please refer to notes on About WWVB Radio controlled Time and Manual Time Setting Your Weather Projection Station is now operational Note If the Weather...

Page 8: ...ure for every 5 seconds 3 Adjust the projection image in an upright position with the key Note If more than one Thermo hygro Sensor is used only the temperature from sensor 1 will be projected Note Th...

Page 9: ...ime which is also known as Greenwich Mean Time GMT This time does not follow Daylight Saving Time changes After the top of the minute a tone will sound for every second It is possible that your Weathe...

Page 10: ...age direction can display 4 different orientations Back light on DISPL key Toggle between the time and outdoor temperature or automatic alternates time outdoor temperature every 5 seconds display mode...

Page 11: ...ss and hold for 4 seconds to reset the MIN MAX records for selected channel Press to set the alarm minute inside alarm setting mode Stop the alarm during alarm ringing Stop snooze mode Back light on A...

Page 12: ...digit starts flashing 2 Use the CH key to view all levels of contrast 3 Select the desired LCD contrast Confirm with the SET key and enter in the Time Zone setting TIME ZONE SETTING The time zone defa...

Page 13: ...n can be turn OFF The clock will then work as a normal Quartz clock Default setting is ON 1 The digit ON will start flashing on the LCD 2 Use the CH key to turn OFF the time reception function 3 Confi...

Page 14: ...on attempts the WWVB tower icon will flash If reception has been unsuccessful then the WWVB tower icon will not appear but reception will still be attempted the following hour CALENDAR SETTING The dat...

Page 15: ...how temperature data in F or C Default F 1 Use the CH key to toggle between F or C 2 Confirm with the SET key and enter the Weather forecasting icon sensitivity setting WEATHER FORECASTING ICON SENSIT...

Page 16: ...m is ringing by pressing the SNOOZE key However the snooze will only be activated when the snooze time is set other than OFF in snooze setting Otherwise the snooze function will not be activated When...

Page 17: ...AST AND WEATHER TENDENCY WEATHER FORECASTING ICONS Weather icons in the third section of LCD that can be displayed in any of the following combinations Sunny Cloudy with sunny intervals Rainy For ever...

Page 18: ...stly sunny If the Weather Projection Station is moved to another location significantly higher or lower than its initial standing point for example from the ground floor to the upper floors of a house...

Page 19: ...d data will also be displayed in the time and calendar sections for temperature data only 2 To reset the MIN MAX data press and hold the HOUR IN key for about 4 seconds This will reset all recorded in...

Page 20: ...r sensor TO EXIT THE MANUAL SETTING MODE To exit the manual setting mode anytime during the manual setting modes press the SNOOZE key anytime or wait for automatic timeout The mode will return to norm...

Page 21: ...ers from the sensor to the Weather Projection Station in open space However this depends on the surrounding environment and interference levels If no reception is possible despite the observation of t...

Page 22: ...esolution OFL displayed if outside this range Relative humidity measuring range Indoor and outdoor 1 to 99 with 1 resolution displayed if outside this range Indoor temperature checking interval every...

Page 23: ...o charge as stipulated herein with new or reconditioned parts or products if found to be defective during the limited warranty period specified above All replaced parts and products become the propert...

Page 24: ...ILL NOT ASSUME LIABILITY FOR INCIDENTAL CONSEQUENTIAL PUNITIVE OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES...

Reviews: