background image

 

successful the reception is tried for 40 seconds on 910MHz. This will also be done for re-
synchronization. 

 

IMPORTANT:  

Transmission problems will arise if the setting for additional transmitters is not followed as 
described above. Should transmission problems occur, it is necessary to remove the batteries 
from all units and start again the set-up from step 1. 

 

HOW TO INSTALL AND REPLACE BATTERIES IN THE TEMPERATURE TRANSMITTER 

The Temperature transmitter uses 2 x AA, IEC LR6, 1.5V batteries. When 
batteries will need to be replaced, the low battery icon will appear on the 
LCD of the Temperature Station. To install and replace the batteries, please 
follow the steps below: 
1.  Remove the battery compartment cover. 
2. 

Insert the batteries, observing the correct polarity (see marking). 

3.  Replace the battery holder to the unit. 

 

Note: 

In the event of changing batteries in any of the units, 

all

 units need to be 

 

10 

reset by following the setup procedures. This is because a random security code is assigned by 
the transmitter at start-up and this code must be received and stored by the Temperature 
Station in the first few minutes of power supplying.

 

 

HOW TO INSTALL AND REPLACE BATTERIES IN THE TEMPERATURE STATION 

The Temperature Station uses 2 x AAA, IEC LR3, 1.5V batteries. 
When batteries will need to be replaced, the low battery icon will 
appear on the LCD. To install and replace the batteries, please follow 
the steps below: 
1. 

Lift up the battery compartment cover. 

2. 

Insert batteries observing the correct polarity (see marking). 

3. 

Replace compartment cover.

 

 
 

 

BATTERY CHANGE: 

It is recommended to replace the batteries in all units every 12 months to ensure optimum 
accuracy of these units. 

 

 

11 

Please participate in the preservation of the environment. Return used batteries 
to an authorised depot. 

 
 

FUNCTION KEYS: 

 

Temperature Station: 

The Temperature Station has only four easy to use function keys. 

 
 
 
 
 
 
 

 
 
 
 

+ key 

Min/max key 

Set Key 

Channel key 

 

12 

SET key (Setting) 

 

Press and hold for about 3 seconds to enter the Manual setting mode: 12/24 hour time 
display, and manual time settings  

 

MIN/MAX key (Min/ Max temperature) 

 

Used to toggle between the minimum and maximum recorded readings of indoor & 
outdoor temperature. 

 

Press and hold to reset minimum and maximum record when min or max record is shown. 

 

+ key (Plus) 

 

To make adjustments for manual settings. 

 

CH key (Channel) 

 

To toggle between the Outdoor transmitters 1, 2 and 3 (if more than 1 transmitter is used) 

 

 
 

Summary of Contents for Wireless Temperature Station

Page 1: ...ifications 32 Warranty Information 33 3 INVENTORY OF CONTENTS 1 Wireless Temperature Station 2 Wireless Outdoor Temperature Transmitter TX29U IT and mounting bracket 3 Instruction Manual This product offers INSTANT TRANSMISSION is the state of the art new wireless transmission technology exclusively designed and developed by LA CROSSE TECHNOLOGY INSTANT TRANSMISSION offers you an immediate update ...

Page 2: ...ter is used 1 User shall remove all the batteries from the Temperature Station and transmitters and wait 60 seconds if setting has been done with one transmitter first 2 Insert the batteries to the first transmitter 3 Within 30 seconds of powering up the first transmitter insert the batteries to the Temperature Station Once the batteries are in place all segments of the LCD will light up briefly F...

Page 3: ...few minutes of power supplying HOW TO INSTALL AND REPLACE BATTERIES IN THE TEMPERATURE STATION The Temperature Station uses 2 x AAA IEC LR3 1 5V batteries When batteries will need to be replaced the low battery icon will appear on the LCD To install and replace the batteries please follow the steps below 1 Lift up the battery compartment cover 2 Insert batteries observing the correct polarity see ...

Page 4: ...TEMPERATURE UNIT C F SETTING To display the time in 12 hour or 24 hour mode default setting 12h 1 In normal display mode press and hold the SET key for about 3 seconds The 12h or 24h digit will be flashing 2 Press the key to set the desired time display mode 3 Press shortly the SET key to advance to the MANUAL TIME SETTING Note When the time display is set as 12 hour mode the temperature unit will...

Page 5: ...lease check the following points 1 The distance of the Temperature Station or transmitter should be at least 5 to 6 5 feet 1 5 to 2 meters away from any interfering sources such as computer monitors or TV sets 2 Avoid positioning the Temperature Station onto or in the immediate proximity of metal window frames 3 Using other electrical products such as headphones or speakers operating on the same s...

Page 6: ...er wall base place all units in the desired locations to check that the outdoor temperature reading is receivable In event that the signal is not received relocate the transmitter s or move them slightly as this may help the signal reception CARE AND MAINTENANCE Extreme temperatures vibration and shock should be avoided as these may cause damage to the unit and give inaccurate forecasts and readin...

Page 7: ...pping charges to the owner of the product to a USA address only Your La Crosse Technology Ltd warranty covers all defects in material and workmanship with the following specified exceptions 1 damage caused by accident unreasonable use or neglect including the lack of reasonable and necessary maintenance 2 damage occurring during shipment claims must be presented to the carrier 3 damage to or deter...

Page 8: ...or chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the next issue We accept no liability for technical mistakes or printing errors or their consequences All trademarks and patents are acknowledged ...

Reviews: